background image

CAST-IRON MULTI-FUEL STOVE v5.2 

INSTALLATION AND 

OPERATING INSTRUCTIONS

LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER !

THE INSTALLATION AND SERVICING OF THIS APPLIANCE MUST BE SUPERVISED BY A 

QUALIFIED SOLID FUEL ENGINEER. THE SUPPLIERS WILL ACCEPT NO RESPONSIBILITY 

WHATEVER FOR APPLIANCES NOT SO INSTALLED.

 

A register of qualified engineers is available from:

UK: The Solid Fuel Association, 7 Swanwick Court Alfreton Derbyshire DE55 7AS Tel:0845-601-4406 www.solidfuel.co.uk

RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 www.fireplace.ie

This document is a guide to installing and using the Tiger stove, any 

national or local regulations must be complied with. In the UK this 

includes British Standards BS8303 (installation) and BS6461 (chimneys 

and flues). 

ASBESTOS: 

Tiger does not contain asbestos, but you should be careful 

to avoid disturbing any asbestos when removing an old installation. 

FIRE CEMENT 

is caustic - wash your hands thoroughly after using it. 

WEIGHT

 Protect your spine by moving the stove only with assistance.

FUME EMISSION:

 Properly installed and operated this appliance will not 

emit   fumes   into   the   dwelling.   Occasional   fumes   from   de-ashing   and 

refuelling  may occur.  However,  persistent  fume  emission  is potentially 

dangerous and must not be tolerated. If fume emission persists, then the 

following immediate action should be taken:

(a) open doors and windows to ventilate the room. (b) let the fire go out or 

eject and safely dispose of fuel from the appliance. (c) check the flue or 

chimney for blockage and clean if required. (d) do not attempt to re-light 

the   fire   until   the   case   of   the   fume   emission   has   been   identified   and 

corrected. If necessary seek expert advice

HEAT:  

The   surfaces   of   the   appliance   and   the   attached   fluepipe   will 

become 

extremely

 hot- a fireguard should be used if children or the infirm 

are present. Flammable materials (including fuel) should not be stored 

near to the appliance. If the Hi-Leg unit is fitted and used as a log store, 

logs must not be placed higher than the central 'bridging' member.

BEFORE YOU BEGIN...

CHIMNEY 

Your chimney creates the draught which Tiger needs in order to work - it

 must

:

Conform to local building regulations.

Be at least 5m high.

Terminate at least 1m above any roof ridge.

Have an internal cross-section not less than 0.018m² (eg 150mm dia) and not more than 0.14m² (eg 375 x 375mm)

Be free from even the slightest crack or source of leakage.

Have no bends sharper than 45 degrees.

Be entirely free of obstructions and swept by a qualified chimney sweep.

Be connected only to the one appliance.

Have a wall thickness of at least 100mm throughout its length, or be thoroughly insulated

New masonry chimneys should be fitted with ceramic liners of at least 200mm diameter.

Prefabricated chimneys should be fully insulated, of at least 150mm internal diameter, conform to BS4543 Part 2 and 
be installed in accordance with the manufacturer's instructions.

INSTALLATION CLEARANCES

  The stove must  be placed on a solid non-combustible hearth at least 150mm  thick 

(which may include the thickness of a solid floor) extending at least 150mm to each side of the stove, 300mm in front and 

50mm at the rear. Any combustible materials (such as a wooden mantleshelf) MUST be at least 300mm away. If the Hi-

Leg unit is fitted and used as a log store, logs must not be placed higher than the central 'bridging' member.

LOAD BEARING  

Tiger is heavy - take care to ensure that the floor has adequate load-bearing capacity and consider 

fitting a load distributing plate if necessary

1

APPLIANCE SPECIFICATION 

Output: Dry Wood logs, 1.5hr 

refuel:

4.5kW

Output: Bituminous coal, 4hr refuel: 5.8kW

Output:  Anthracite, 4hr refuel: 

5.9kW

Output:  Hard Coke, 4hr refuel: 

4.4kW

Output: Peat Briquettes, 4hr refuel:  4.4Kw

Output:  Lignite, 4hr refuel: 

3.75kW

Mass

97 kg

Minimum flue draught

12Pa

Flue gas flow

12g/sec

Average flue gas temperature

305°C

Maximum fuel load (anthracite)

7.93kg

en

13240:2001

This appliance conforms to the constructional 

requirements of EN13240