background image

CAST-IRON MULTI-FUEL STOVE v5.2 

INSTALLATION AND 

OPERATING INSTRUCTIONS

LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER !

THE INSTALLATION AND SERVICING OF THIS APPLIANCE MUST BE SUPERVISED BY A 

QUALIFIED SOLID FUEL ENGINEER. THE SUPPLIERS WILL ACCEPT NO RESPONSIBILITY 

WHATEVER FOR APPLIANCES NOT SO INSTALLED.

 

A register of qualified engineers is available from:

UK: The Solid Fuel Association, 7 Swanwick Court Alfreton Derbyshire DE55 7AS Tel:0845-601-4406 www.solidfuel.co.uk

RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 www.fireplace.ie

This document is a guide to installing and using the Tiger Plus stove, 

any  national   or   local   regulations   must   be   complied   with.   Building 

regulations   for   the   UK,   RoI   and   IoM   can   be   found   at 

www.tigerstoves.com

ASBESTOS:  

Tiger  does  not  contain  asbestos,  but  you  should  be 

careful   to   avoid   disturbing   any   asbestos   when   removing   an   old 

installation. 

FIRE CEMENT 

is caustic - wash your hands thoroughly after using it. 

WEIGHT

  Protect   your   spine   by   moving   the   stove   only   with 

assistance.

FUME EMISSION:

 Properly installed and operated this appliance will 

not emit fumes into the dwelling. Occasional fumes from de-ashing 

and   refuelling   may   occur.   However,   persistent   fume   emission   is 

potentially dangerous and must not be tolerated. If fume emission 

persists, then the following immediate action should be taken:

(a) open doors and windows to ventilate the room. (b) let the fire go 

out or eject and safely dispose of fuel from the appliance. (c) check 

the flue or chimney for blockage and clean if required. (d) do not 

attempt to re-light the fire until the case of the fume emission has 

been identified and corrected. If necessary seek expert advice

HEAT:  

The surfaces of the appliance and the attached fluepipe will 

become 

extremely

 hot- a fireguard should be used if children or the 

infirm are present. Flammable materials (including fuel) should not 

be stored near to the appliance. If the Hi-Leg unit is fitted and used as a log store, logs must not be placed higher than the 

central 'bridging' member.

BEFORE YOU BEGIN...

CHIMNEY 

Your chimney creates the draught which Tiger needs in order to work - it

 must

:

Conform to local building regulations.

Be at least 5m high.

Terminate at least 1m above any roof ridge.

Have an internal cross-section not less than 0.018m² (eg 150mm dia) and not more than 0.14m² (eg 375 x 375mm)

Be free from even the slightest crack or source of leakage.

Have no bends sharper than 45 degrees.

Be entirely free of obstructions and swept by a qualified chimney sweep.

Be connected only to the one appliance.

Have a wall thickness of at least 100mm throughout its length, or be thoroughly insulated

New masonry chimneys should be fitted with ceramic liners of at least 200mm diameter.

Prefabricated chimneys should be fully insulated, of at least 150mm internal diameter, conform to BS4543 Part 2 and 

be installed in accordance with the manufacturer's instructions.

INSTALLATION CLEARANCES

  The stove must be placed on a solid non-combustible hearth conforming to building 

regulations.   There   must   be   no   combustible   material,   including   fuel,   within   40cm.   If   the   Hi-Leg   unit   is   fitted   hearth 

temperature will not exceed 100ºC, and light duty hearth material may be used.

LOAD BEARING  

Tiger is heavy - take care to ensure that the floor has adequate load-bearing capacity and consider 

fitting a load distributing plate if necessary

1

Conforms to EN13240

Independently tested by SGS 
Arnheim, 2007
Approved Laboratory No 0608

Fuel

Wood (Beech)

Mineral Fuel

(Ancit)

Efficiency

77.50%

78.20%

Max.  Output

6kW

6kW

CO Emission

(as if at 13% O2)

0.37%vol

0.15%vol

Mean Flue 

Temperature

312º C

240ºC

Clearance to 

combustibles

40cm

40cm

Smoke Emission

286 mg/m³ 

81 mg/m³

Gas flow

5.4 g/sec

6.3 g/sec

Flue Draught

Min 12Pa

Min 12Pa