60
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
·
Failover and SmartStream PLUS redundant streaming are not available with SIP
connections.
·
When connecting to a Tieline G3 codec using SIP you need to manually select the G3
audio reference level in the codec. To do this select
SETTINGS
> Audio > Ref
Level > Tieline G3
. In addition, configure the following on the G3 codec prior to
dialing:
Select either a mono or stereo profile
Select
[Menu] > [Configuration] > [IP1 Setup] > [Session Type] > [SIP]
Select
[Menu] > [Configuration] > [IP1 Setup] > [Algorithm] > [G711/G722 or
MP2]
14.1
Configuring SIP Interfaces
The codec supports dialing over two SIP interfaces simultaneously.
Important Notes:
1. SIP interfaces are disabled by default.
2.
SIP1
is configured to use
ETH1
by default, which is mapped to the
Primary
Via
interface by default.
3.
SIP2
is configured to use
ETH2
by default, which is mapped to the
Secondary
Via
interface by default.
4.
SIP1
and
SIP2
each need to use a separate IP interface when connecting, e.g.
ETH1
or
ETH2
.
5.
SIP1
and
SIP2
can however each make multiple SIP calls, e.g. two calls can be
made over
SIP1
, or two calls can be made over
SIP2
.
6. The settings for
SIP1
and
SIP2
cannot be edited if the interface is enabled.
7. Enter a public IP address in the
Public IP
text box if you want to dial over SIP from
behind a firewall. Then configure port forwarding to route traffic to the codec's local IP
address behind your firewall. Note: Do not enter a
Public IP
address if STUN is
configured. They cannot be used together because both will attempt to use a public IP
address over SIP. STUN settings are prioritized and used if both are configured.
To configure
SIP1
or
SIP2
:
1. Press the
SETTINGS
button, then navigate to
SIP
and press the
button.
2. Navigate to
Interfaces
and press the
button.
3. Select either
SIP1
or
SIP2
and press
.