117
© Tieline Research Pty. Ltd. 2019
Bridge-IT Manual v4.0
16.9
Configuring Multi-Unicast Dialing Programs
The codec can transmit a mono or stereo multi-unicast audio stream to a maximum of 6
endpoints in total. The first connection in a multi-unicast program is capable of bidirectional audio.
Multi-unicast connections can only be created using the ToolBox web-GUI and require a software
license which supports multi-unicasting.
Prerequisites:
·
Bridge-IT firmware v.1.01.00 r4219 or higher.
·
G3 codec firmware v.1.6.56 or higher (if connecting to a G3 codec).
·
ToolBox web-GUI v.1.2.2.3 or higher.
·
A
multi-unicast license installed
Important Notes:
Before you start program configuration please note:
·
You cannot edit a program when it is currently loaded in the codec.
·
You can
in a codec to ensure the currently loaded
program cannot be unloaded by a codec dialing in with a different program type.
·
If you are dialing to both G3 and Bridge-IT, Merlin or Genie codecs, by default the
Audio Reference Level will be configured for the compatibility of the codec dialed
first. I.e. if you dial a G3 codec first then the G3 Audio Reference Level will be
configured for all connections.
·
Connections are dial only for multi-unicast programs.
·
Some drop-down menus and settings may be greyed out intentionally depending on
features available.
·
It is possible to save a program at several points throughout the program wizard and
use default settings to save configuration time. The first connection in each multi-
unicast stream determines default settings (e.g. algorithm, sample rate, bit rate), for
all subsequent connections in that stream, except for dialing settings.
·
All algorithms are supported for multi-unicast connections, however only one can be
used per audio stream.
·
Select any algorithm for multi-unicast connections except aptX Enhanced and PCM.
·
Bidirectional audio is only available on the first connection dialed.
·
SmartStream PLUS and FEC is not available for multi-unicast connections.
·
Renegotiation of connection bit rates is not possible when connected.
·
Ensure you have sufficient connection bandwidth at the local codec to support all the
connections to which you are connecting.
·
To learn more about programs see the section titled
Creating a Multi-Unicast Program
1. Open the HTML5 Toolbox Web-GUI and click
Connect
in the
Menu Bar
, then select
Program
Manager
to launch the
Program Manager panel
.
Summary of Contents for Bridge-IT
Page 15: ...15 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0 Codec Menu Overview...
Page 16: ...16 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 Connect Menu...
Page 17: ...17 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0 IP Setup Menu Navigation...
Page 18: ...18 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 Settings Menu...
Page 158: ...158 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 4 Click Yes in the confirmation dialog...
Page 217: ...217 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0...