PRO-SPOTTER
HEATING AND AIR CONDITIONING
TICO Manufacturing
Service Manual
15-7
Recover R134a Refrigerant
CAUTION
1.
Handle refrigerant safely. (See “R134a
REFRIGERANT HOSES AND TUBING” on
page 15-4.)
2.
Park and prepare tractor for service. (See “Park
Tractor Safely” on page 1-3.)
CAUTION
IMPORTANT
Prevent possible air conditioning system damage.
Use correct refrigerant recovery, recycling, and
recharging stations. Do not mix refrigerant, hoses,
fittings, components, or refrigerant oils.
3.
Run air conditioning system for 3 minutes to help in
recovery process.
4.
Turn air conditioning system off before proceeding
with recovery steps.
5.
With engine OFF, connect refrigerant recovery,
recycling, and charging station. (See “R134a
REFRIGERANT RECOVERY, RECYCLING, AND
RECHARGING STATION” on page 15-6.)
6.
Follow manufacturer’s instructions when using
refrigerant recovery, recycling, and recharging
station.
Evacuate R134a System
CAUTION
1.
Handle refrigerant safely. (See “R134a
REFRIGERANT HOSES AND TUBING” on
page 15-4.)
2.
Park and prepare tractor for service. (See “Park
Tractor Safely” on page 1-3.)
CAUTION
IMPORTANT
Prevent possible air conditioning system damage.
Use correct refrigerant recovery, recycling, and
recharging stations. Do not mix refrigerant, hoses,
fittings, components, or refrigerant oils.
3.
Connect refrigerant recovery, recycling, and charging
station. (See “R134a REFRIGERANT RECOVERY,
RECYCLING, AND RECHARGING STATION” on
page 15-6.)
4.
Open low and high-pressure valves on refrigerant
recovery, recycling, and recharging station.
5.
Follow manufacturer’s instructions and evacuate
system.
NOTE
Vacuum specifications listed are for sea level conditions.
Subtract 3.4 kPa (34 mbar) (1 in Hg) from 98 kPa (980
mbar) (29 in Hg) for each 300 m (1000 ft) elevation above
sea level.
6.
Evacuate system until low-pressure gauge registers
specified vacuum.
If specified vacuum cannot be obtained in 15
minutes, a leak may be present. Locate and repair
leak. (See “R134a REFRIGERANT LEAK TEST” on
page 15-5.)
Prevent refrigerant from contacting eyes or skin.
Refrigerant will freeze eyes or skin on contact.
Wear goggles, gloves, and protective clothing.
Avoid possible injury from air conditioning
system refrigerant. Do not remove high-pressure
relief valve. Air conditioning system will
discharge rapidly.
Prevent refrigerant from contacting eyes or skin.
Refrigerant will freeze eyes or skin on contact.
Wear goggles, gloves, and protective clothing.
Avoid possible injury from air conditioning
system refrigerant. Do not remove high-pressure
relief valve. Air conditioning system will
discharge rapidly.
Summary of Contents for Pro-Spotter
Page 1: ...TICO Manufacturing Service Manual 4 4 37 6 TICO Manufacturing 1 30 2018 130 41055 3...
Page 2: ...Pro Spotter Service Manual TICO Manufacturing...
Page 12: ...0 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 28: ...1 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 44: ...2 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 56: ...3 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 68: ...4 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 92: ...6 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 114: ...8 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 122: ...9 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 130: ...10 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 134: ...11 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 144: ...12 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 154: ...13 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 184: ...15 0 Service Manual TICO Manufacturing PRO SPOTTER...
Page 204: ...IDX 0 Service Manual TICO Manufacturing PRO SPOTTER...