background image

 

HA0415T 

 

 

 

PWA120 

Ø1.5" Accessory  
Adapter for Breadboard  
Frames 

Installation Manual 

 

 
 
 
 
 
 
 

Original Instructions 

Summary of Contents for PWA120

Page 1: ...HA0415T PWA120 1 5 Accessory Adapter for Breadboard Frames Installation Manual Original Instructions...

Page 2: ...1 Load Capacity 2 2 2 Fitting to a PFR Series Rigid Mount Frame 3 2 3 Fitting to a PFP Series Standard Passive Mount Frame 4 2 4 Fitting to a PFH Series Heavy Duty Passive Mount Frame 5 2 5 Installing...

Page 3: ...duct itself Warning Given when there is a risk of injury to the user Caution Given when there is a possibility of damage to the product Note Clarification of an instruction or additional information 1...

Page 4: ...plate can accommodate up to 40 kg 88 lbs of vertical load Warning Do not exceed the 40 kg 88 lbs maximum vertical load capacity for each adapter plate Description Qty Image Accessory Adapter Plate 1 M...

Page 5: ...dapter into place over the mount 2 Align the four outer holes on frame top plate with the holes in the adapter plate The adapter plate can be rotated 90 degrees if a different orientation is required...

Page 6: ...r into place over the body of the passive mount 2 Align the four outer holes on frame top plate with the holes in the adapter plate The adapter plate can be rotated 90 degrees if a different orientati...

Page 7: ...ut leave the mount in place 2 Slide the adapter into place over the body of the passive mount 3 Align the four outer holes on frame top plate with the holes in the adapter plate The adapter plate can...

Page 8: ...in the washers 2 Align the post with one of the three post holes on the adapter plate central hole recommended 3 Using the washers removed at item 1 and the included M16 x 35 mm bolt and 14 mm hex key...

Page 9: ...loads should be placed on a shelf in a lower position otherwise the stability of the frame could be affected The center of mass of the experimental setup as a whole should remain within the frame are...

Page 10: ...loads should be placed in a low position otherwise the stability of the frame could be affected The center of mass of the experimental setup as a whole should remain within the frame area Do not excee...

Page 11: ...t wheelie bin logo see right were sold to and are currently owned by a company or institute within the EC and are not dissembled or contaminated Contact Thorlabs for more information Waste treatment i...

Page 12: ...www thorlabs com...