background image

© 2016 Thorlabs

16

BC106N

3.2   Setting up

The M2MS Measurement System is a complete  system  that  is  factory  aligned.  The  mounting
adapter  for  the  beam  profiler  provides  a  secure  and  reproducible  positioning  of  the  beam
profiler's input aperture to the M2MS. This eases the mechanical setup. 

 Note 

It  is  strongly  recommended  to  fix  the  M2MS  properly  to  the  optical  table  using  the  four  rail
clamps, included in the M2MS Accessory Box. Therefor remove the rubber feet from the M2MS
base plate, this ensures the proper mounting.

Transportation Lock and Stop Position Latch

In order to avoid transportation damages to the translation stage, it is locked when delivered.
This  lock  must  be  removed  prior  to  power-up  the  stage,  and  it  must  be  re-installed  for
transportation!  Additionally,  the  DDSM100  stage  is  fixed  at  it's  initial  position  -  in  the  photo
below that is the left stop - by a latch that is controlled by a solenoid. This latch fixes the stage
when the power supply is switched off and releases with power-on.

Removal of the Transportation Lock

1. Remove the 4 screws fixing the top cover using a 0.05" hex key (supplied with M2MS)

and remove the cover.

2. Remove the M4 screw that fixes the red stopper, and remove the stopper (3 mm ball

driver included with the accessory box). Keep the stopper and the fixing screw in a safe
place.

1 - Transportation Lock

2 - Electromagnetic Endpoint Latch

3. Close the M2MS.

Summary of Contents for M2MS-BC106N Series

Page 1: ...Thorlabs Beam Beam Analyzing Software BC106N M2MS BC106N Series Quick Start 2016...

Page 2: ...Copyright 2016 Thorlabs Version Date Item No 6 2 13 Jul 2016 M0009 510 712...

Page 3: ...ation 7 2 5 1 Software Installation 14 2 5 2 Connection to the PC 14 2 5 3 Start the Application 3 Beam Quality M Measurement 15 15 3 1 M Meter Set with BC106N Camera Beam Profiler 16 3 2 Setting up 1...

Page 4: ...ternational partners are looking forward to hearing from you Thorlabs GmbH Warning Sections marked by this symbol explain dangers that might result in personal injury or death Always read the associat...

Page 5: ...o the protective earth contact of the socket outlet Improper grounding can cause electric shock with damages to your health or even death The Beam Profiler must not be operated in explosion endangered...

Page 6: ...the M2MS Extension and a mounted BC106N beam profiler The following models are available Item Number Description M2MS BC106UV AL M2 Measurement System with BC106N UV 250 350 nm M2MS BC106UV AL M M2 M...

Page 7: ...461 C Plano Convex Lens f 250 mm AR coating 1050 1700 nm 4 pcs CL6 Rail clamps 1 pcs M2MS Adjustment laser 1 pcs Ball Driver 3 mm 1 pcs spare screw M4x10 2 3 Preparation 1 Install the Thorlabs Beam so...

Page 8: ...6N 2 4 Requirements Recommended for optimal performance hardware features USB 2 0 high speed port Processor Core 2 Duo E4300 or A64 X2 3800 AMD 2 0 GB RAM OpenGL specification GLX 1 3 up compatible gr...

Page 9: ...procedure is described for installation to a Windows 7 32 bit operating system Installation to a 64 bit operating system requires additional installation steps first 64 bit components are installed fo...

Page 10: ...2016 Thorlabs 8 BC106N and follow the instructions Click Next to continue...

Page 11: ...2016 Thorlabs 2 Getting Started 9 Click I accept if you do so then Next to continue installation...

Page 12: ...2016 Thorlabs 10 BC106N Click Finish Please reboot the PC when this message appears After restarting the PC the installer continues to install the software If not please execute the setup exe again...

Page 13: ...2016 Thorlabs 2 Getting Started 11 Please read this license agreements carefully choose I agree and click Next It is recommended to follow the recommended path click Next and then Install to proceed...

Page 14: ...confirmation to install the Thorlabs USB driver You may check the box Always trust software from Thorlabs GmbH this will shorten the installation However if you do not want to do that please click th...

Page 15: ...2016 Thorlabs 2 Getting Started 13 Now all drivers are installed and the Read Me comes up Click Next then Finish to complete the software installation...

Page 16: ...ay not be able to deliver the specified max current 500mA After connecting the instrument to the PC the Windows 7 operating system will load the appropriate USB drivers for the Beam Profiler instrumen...

Page 17: ...u bar Menu Windows or by clicking the icon in the tool bar 3 1 M Meter Set with BC106N Camera Beam Profiler M2MS BC106 set features Accurate M measurements Measures divergence waist diameter Rayleigh...

Page 18: ...damages to the translation stage it is locked when delivered This lock must be removed prior to power up the stage and it must be re installed for transportation Additionally the DDSM100 stage is fix...

Page 19: ...ire USB 2 0 specifications The operation systems Windows 7 and 8 are less tolerant to deviation from this specification than former operating systems The use of other than the supplied USB 2 0 cables...

Page 20: ...s operating system recognizes the connected new hardware and performs the driver installation Note The USB Test and Measurement Device IVI and the APT USB Device are hardware components of the M2MS ex...

Page 21: ...service does not refer to other Thorlabs products such as pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards components mechanics and optics left o...

Page 22: ...tware determined by Thorlabs for this unit to operate fault free provided that they are handled according to our requirements However Thorlabs does not warrant a fault free and uninterrupted operation...

Page 23: ...this product In no event shall any liability exceed the purchase price of the product Please note that the content of this User Manual is neither part of any previous or existing agreement promise rep...

Page 24: ...labs Sweden AB M lndalsv gen 3 412 63 G teborg Sweden Tel 46 31 733 30 00 Fax 46 31 703 40 45 www thorlabs com Email scandinavia thorlabs com France Thorlabs SAS 109 rue des C tes 78600 Maisons Laffit...

Reviews: