background image

                                                                             

DFT-6600 Battery Charger-Discharger Users Manual 

Introduction

 

 

The DFT-6600 Tester

 

is specially designed for verification discharge testing, capacity testing, daily battery string 

maintenance, engineering acceptance and other DC power supply load capacity testing of battery string: 

 

Using the latest Wi-fi communication technology, the battery discharge process can be monitored in real time 

through the PC monitoring software, and the discharge process of each battery can be monitored. 

 

The power consumption part adopts the new efficient resistor as the discharge load, which completely avoids 

the red-heat phenomenon for more safe and reliable and nonpolluting. 

 

The whole tester is controlled by a microprocessor on LCD display & English menu. 

 

The host design is novel, small size, light weight and portable. 

 

The  entire  constant  current  discharge  process  is  automatically  completed  after  the  various  discharge 

parameters are set,   

 

Fully smart control to make the entire discharge process safer. 

The DFT-6600 Tester is to make the discharge test work simple and easy, which is not only to greatly reduce the 

labor  intensity  of  professional  maintenance  personnel,  but  also  to  improve  the  scientific  and  smart  control 

discharge testing. 

 

The

 

DFT-6600  Tester  combines  battery  testing  technology,  Wi-Fi  communication  technology,  computer 

information  processing  and  other  technologies,  to  launch  a  new  generation  of  discharge  tester  with  Wi-Fi 

single-cell detection functions: 

By  the  use  of  Wi-Fi  transmission  single-cell  voltage  acquisition  system,  it  can  be  short  distance  Wi-Fi 

communication  transmission  data,  data  acquisition  speed,  high  precision,  strong  anti-interference  ability,  easy 

operate, which can also record the battery discharge process of each time period of voltage changes, and effectively 

avoid the error caused by the connection and connection cable damage and other safety hazards.   

The  single-cell  bridge  voltage  Wi-Fi  collection  between  the  battery  connection  wire  is  to  ensure  that  even  if 

individual  connectors  loose  in  the  discharge  process  may  cause  large  connection  resistance,  it  can  also  monitor 

individual voltage abnormalities, Eliminate hidden dangers in time, and prevent major accidents such as fire caused 

by overheating at the joint, which enhance the stability and reliability of the system, and expand the use scope of 

the DFT-6600 Tester. 

Summary of Contents for DFT-6600

Page 1: ...DFT 6600 Battery Charger Discharger Users Manual THOMSON TECH CO LTD www thomsontesting com...

Page 2: ...l index 9 Chapter 2 Shape and structure 11 2 1 The host schematic diagram 11 2 2 Package List 12 Chapter 3 Connection 15 3 1 Preparations 15 3 2 Host connection 15 3 3 Cell Data Case connection 18 3 4...

Page 3: ...to greatly reduce the labor intensity of professional maintenance personnel but also to improve the scientific and smart control discharge testing The DFT 6600 Tester combines battery testing technol...

Page 4: ...er which not only increases the purchase cost of the users but also because the connection cable is more and longer it is easy to cause connection errors and it is impossible to avoid the safety hazar...

Page 5: ...It is important to take the correct testing steps to avoid injury to yourself and others in the work area and to detect damage to your equipment Ensure that the operator has a comprehensive understand...

Page 6: ...in or snow or in a humid environment Do not allow battery gas or sulfuric acid to touch the tester s housing Never charging testing or loading to a frozen battery The battery should be thawed and warm...

Page 7: ...g of batteries real time online display detection recording of the voltage of a single cell or the entire String of batteries storing or transmitting the data to the PC Large screen LCD display full E...

Page 8: ...ction Set the discharge and charging cycles No and activate the battery string Automatic Stop function It can automatically stop discharging charging when any of the following conditions are met time...

Page 9: ...The power consumption component adopts new efficient resistor which is safe redfree heat phenomenon and has a long life The application of single chip microcomputer to U disk data transfer technology...

Page 10: ...DFT 6600 Battery Charger Discharger Users Manual 9 1 4 Working schematic diagram...

Page 11: ...425 638 500 600 178 380 403 525 732 980 706 500 52 2 Host Weight Kg 15 45 60 55 80 65 Sampling accuracy Total voltage resolution 10mV accuracy 0 1V Single cell voltage resolution 1mV accuracy 10mV Cu...

Page 12: ...DFT 6600 Battery Charger Discharger Users Manual 11 Chapter 2 Shape and structure 2 1 The host schematic diagram Figure 2 1 DFT 6600 series tester Host images only for reference...

Page 13: ...harge and discharge cable 1 Red 1 Black 4 U disk 1 5 Power Lead 1 6 Ground wire 1 7 Instruction manual 1 8 Box 1 Cell Data Case optional with PC Data Software No differ to 2V 4V 6V 12V etc 9 Cell Data...

Page 14: ...DFT 6600 Battery Charger Discharger Users Manual 13 Box String Voltage line Charge and discharge cable Cell Data Case voltage line 12 Red Cell 1 Black Ground Cell Data Case 2V 6V 12V Antenna...

Page 15: ...DFT 6600 Battery Charger Discharger Users Manual 14 Cell Data Case ramp 12 Red 1 Black Power Lead 380V 6pin...

Page 16: ...e around the battery string and the DFT 6600 Tester There are No flammable and explosive materials around the site There are No flammable and explosive gases in the air Check that the DFT 6600 Tester...

Page 17: ...ower on Note a If there is a spark found in the process of discharging the cable clip battery string electrode please remove the clip stop the discharge testing and contact the THOMSON b When wiring f...

Page 18: ...current in order to accurately measure the voltage of the battery string a Special voltage test line is provided One end of the voltage test line is connected to the voltage test socket of the DFT 66...

Page 19: ...se connection Cell Data Case is for each cell voltage sampling of max 12 Cell which is with magnetized screws for easy fixing standby 3 4 Running After checking that the wiring is correct turn on the...

Page 20: ...harge Test to enter the discharge settings interface At this point you need to set the site No Battery string No Voltage level Battery type batteries No Nominal capacity Discharge capacity the paramet...

Page 21: ...interface Press the V I Trend icon to enter the following interface 4 3 Battery Charge In the main menu press the Charging Test icon to enter the charging settings interface As shown in the following...

Page 22: ...ative or total positive option After setting the charging parameters press the Even or Float button enters the charging mode selection Even charge current Float charge voltage Total charge time Max ev...

Page 23: ...rging stop voltage 13 20V b For small capacity batteries you should also pay attention to the setting of the working current It is recommended to charge discharge at a rate of 0 1C i e the operating c...

Page 24: ...seriously affect the correctness of U disk reading and writing if the reading and writing U disk error please reformat the U disk and try again c Please insert the U disk first and wait until the pro...

Page 25: ...play in the data storage and results printing so it is recommended to adjust the clock before using the tester operation to facilitate the correct output synchronized with the detected data Adjust clo...

Page 26: ...DFT 6600 Battery Charger Discharger Users Manual 25 When inserting a U disk containing upgrade files press the Upgrade button to upgrade the system...

Page 27: ...alcohol etc so as not to damage the text on the host computer 5 1 2 Clamps Cleaning and maintenance Wash the clamps with a soft damp cloth and a mild detergent After cleaning wash it with clean water...