Appendix A ’Technical Specifications’ — Signal Processing
Amethyst III DTV Smart Switch
203
User Manual
Ethernet Control/Command
Table A-8. Gigabit Ethernet interfaces electrical specifications
Connectors
1 RJ-45 port
Speed
10/100 Base T
Control/
Monitoring
modes
Web GUI
Front panel
SNMP v2
GPIs (X6)
Free voltage contacts (X4)
TR101.290 + Template Checking
Table A-9. TR101.290 + template checking specifications
Level of test
Supported tests
Availability
TR 101 290
Level 1
1.1 TS Sync Loss
1.2 Sync Byte Error
1.3.a.1 PAT Interval
1.3.a.2 PID 0 PAT
1.3.a.3 PAT Scrambling
1.4 Continuity Counter
1.5.a.1 PMT Interval
1.5.a.2 PMT Scrambling
1.6.a PID AV Error
1.6.b PID Other Error
Standard platform
+ Advanced
platform
TR 101 290
Level 2
2.1 Transport Error
2.2 CRC Error
2.3.a PCR Repetition
2.3.b PCR Discontinuity
2.4 PCR Accuracy
2.5 PTS Error
2.6.1 CAT Presence
2.6.2 PID 1 CAT
Advanced platform