Page 1: ...Co9 LED Flood IP65 540W RGBW LED floodlight User manual...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 15 02 2018 ID 421760 V2...

Page 3: ...7 2 3 Operating mode Stand alone 19 7 3 Menu overview 20 7 4 Functions in 2 channel DMX mode 21 7 5 Functions in 3 channel DMX mode 1 21 7 6 Functions in 3 channel DMX mode 2 22 7 7 Functions in 4 ch...

Page 4: ...tion in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For perso...

Page 5: ...rd indicates a possible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a possible dangerous situation t...

Page 6: ...within reach of babies and young children Choking hazard Ensure that children do not detach any small parts e g knobs or the like from the unit They could swallow the pieces and choke Never let childr...

Page 7: ...cted by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and when it is unused for...

Page 8: ...ected against contact first code number They are also protected against splash water from any angle second code digit That is why this equipment can also be used out doors Event technology equipment i...

Page 9: ...olt free WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a secondary saf...

Page 10: ...he following figure You can install the unit in hanging or standing position When in use the device must always be attached to a solid surface or an approved truss Always work from a stable platform w...

Page 11: ...the daisy chain is terminated with a resistor 110 W When you configure a group of devices in master slave mode the first unit will con trol the other units for an automatic sound activated synchronize...

Page 12: ...enu and toggles between menu items Closes an opened submenu UP Navigates upwards in a menu list Increases the displayed value by one DOWN Navigates downwards in a menu list Decreases the displayed val...

Page 13: ...OUT DMX output IP65 design 7 POWER OUT Connection supply voltage outgoing Power Twist IP65 8 POWER IN Connection supply voltage incoming Power Twist IP65 Rear panel Connections and controls Co9 LED Fl...

Page 14: ...ly to start operation After a few seconds the display indicates that a reset is in progress The device is then ready for use The dis play shows the operating mode that was selected when the unit was l...

Page 15: ...DMX Address Set DMX address 001 512 Setting the DMX address MODE DMX Signal Select Selection of the DMX transmission type DMX DMX via cable Wireless DMX DMX via radio transmission DMX Mode Selecting...

Page 16: ...ntensity green 0 to 100 Blue 0 255 Intensity blue 0 to 100 White 0 255 Intensity white 0 to 100 Rainbow Rainbow effect 0 5 Effect off 6 21 Rainbow effect 1 22 37 Rainbow effect 2 38 53 Fading green or...

Page 17: ...show 7 181 205 Automatic show 8 206 230 Automatic show 9 231 255 Automatic show 10 Auto speed 0 255 Running speed auto matic show increasing Auto Fade 0 255 Fade speed for auto matic shows Color Macr...

Page 18: ...curve Linear Linear Exp Exponential Log Logarithmic S Curve S shaped Dimmer Response Dimmer characteristic LED Dimmer characteristic LED 3 s delay Halogen Dimmer characteristic Halogen 5 s delay White...

Page 19: ...rating hours display Power on Total operating hours Last run hrs Operating hours since last power up 7 2 1 Operating mode DMX In DMX mode the display shows the set DMX mode in its top row and the DMX...

Page 20: ...ing Automatic Jump effect n Operating Mode STATIC Freely mixable colour with optional rainbow and stro boscopic effect or automatic show n Operating Mode Color Macro Selecting a pre defined colour mac...

Page 21: ...ve 86 93 Magenta 94 101 Pink 102 109 Warm white 110 117 White 118 125 Cold white 126 127 Colour change halted 128 191 Colour change effect increasing speed 192 255 Colour transition effect increasing...

Page 22: ...ve 86 93 Magenta 94 101 Pink 102 109 Warm white 110 117 White 118 125 Cold white 126 127 No function 128 191 Colour change effect increasing speed 192 255 Colour transition effect increasing speed 7 6...

Page 23: ...peed 34 56 Ramp up effect with increasing speed 57 79 Random Ramp down effect with increasing speed 80 102 Random strobe effect with increasing speed 103 127 Strobe burst effect with decreasing durati...

Page 24: ...effect 0 5 Effect off 6 21 Rainbow effect 1 22 37 Rainbow effect 2 38 53 Fading green orange 54 69 Pulse rod orange 70 85 Pulse blue white 86 101 Fading blue yellow 102 117 Rainbow effect 7 118 133 Ra...

Page 25: ...128 191 Logarithmic 192 255 S shaped 13 Special functions Settings are enabled or retained if the corresponding DMX value is held for five seconds 0 5 No function 6 63 Dimmer characteristic LED 3 s d...

Page 26: ...tensity white 0 to 100 LED row 4 7 10 Functions in 29 channel DMX mode Channel Value Function 1 0 255 Dimmer 0 to 100 2 Stroboscope functions 0 5 Open strobe 6 10 Closed strobe 11 33 Random Pulse effe...

Page 27: ...o function 128 191 Colour change effect increasing speed 192 255 Colour transition effect increasing speed 8 Rainbow effect 0 5 Effect off 6 21 Rainbow effect 1 22 37 Rainbow effect 2 38 53 Fading gre...

Page 28: ...10 0 255 Running speed automatic show increasing 11 0 255 Automatic Fade effect 12 Dimmer curve 0 5 No function 6 63 Linear 64 127 Exponential 128 191 Logarithmic 192 255 S shaped 13 Special function...

Page 29: ...255 Intensity white 0 to 100 LED row 2 22 0 255 Intensity red 0 to 100 LED row 3 23 0 255 Intensity green 0 to 100 LED row 3 24 0 255 Intensity blue 0 to 100 LED row 3 25 0 255 Intensity white 0 to 1...

Page 30: ...13 16 or 29 depending on operating mode Power consumption 500 W Operating supply voltage 100 240 V 50 60 Hz Protection class IP65 Temperature range 20 C 45 C Dimensions W H D 585 mm 285 mm 220 mm Wei...

Page 31: ...esult of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show A three pole coupling in IP65 design is used as DMX output a three pole plug in IP65...

Page 32: ...the DMX con troller 1 Check the DMX connectors and cables for proper connection 2 Try using another DMX controller 3 Check to see if the DMX cables run near or alongside to high voltage cables that ma...

Page 33: ...of cleaning depends on the operating envi ronment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using our lamp...

Page 34: ...rkings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste...