Page 1: ...CL 112 CL 115 CL 118 Sub MKII active subwoofer user manual...

Page 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 24 10 2014 ID 341323 341324 341325...

Page 3: ...mbols and signal words 6 2 Safety instructions 8 3 Features 12 4 Installation 13 4 1 Tips on handling speakers 15 5 Connections and operating elements 16 6 Technical specifications 20 7 Plug and conne...

Page 4: ...and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this ma...

Page 5: ...Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal con...

Page 6: ...or connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbol...

Page 7: ...symbol and signal word indicates a pos sible dangerous situation that can result in minor injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous...

Page 8: ...l sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for...

Page 9: ...able parts inside DANGER Electric shock caused by short circuit Always use proper ready made insulated mains cabling power cord with a pro tective contact plug Do not modify the mains cable or the plu...

Page 10: ...ause hearing damage Decrease the volume level immediately if you experience ringing in your ears or hearing impairment If this is not possible keep a greater distance or use suffi cient ear protectors...

Page 11: ...e device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in dam...

Page 12: ...ets RCA sockets CL 115 and CL 118 n Outputs NL4 chassis connectors for passive speaker boxes top DIRECT OUT CL 115 and CL 118 n 36 mm pole mount flange n Butterfly handles n Transport casters n PU coa...

Page 13: ...ial suitable for transport or storage respectively For operation the device must be placed on its rubber feet Therefore tip the unit over its pro tected edge Do not take the device into operation whil...

Page 14: ...are required for trans port and installation NOTICE Possible property damage by magnetic fields Loudspeakers produce a static magnetic field Therefore maintain an appropriate distance to devices that...

Page 15: ...lts both impedance and power handling of the speakers must match the requirements of the amplifier Always follow the technical specifications of the speakers The overall impedance of the connected lou...

Page 16: ...5 Connections and operating elements Rear panel CL 112 SUB MKII Connections and operating elements active subwoofer 16...

Page 17: ...Rear panel CL 115 SUB MKII CL 118 SUB MKII Connections and operating elements CL 112 CL 115 CL 118 Sub MKII 17...

Page 18: ...4 INPUT RIGHT LEFT Inputs for balanced or unbalanced line level signals XLR sockets 5 INPUT RIGHT LEFT Inputs for balanced or unbalanced line level signals RCA sockets 6 POWER This LED indicates that...

Page 19: ...is LED lights up red when the unit switches to protection mode In this case check the cables for short circuit or bad connection If this LED lights constantly please contact our service centre Contact...

Page 20: ...d 2 XLR balanced 2 1 4 bal anced unbalanced 2 RCA 2 XLR balanced 2 1 4 bal anced unbalanced 2 RCA Outputs Lockable NL4 chassis connector 1 1 Lockable NL4 chassis connector 1 1 2 DIRECT OUT XLR Lockabl...

Page 21: ...8 dB max 122 dB max 124 dB max Operating supply voltage AC 220 240 V 50 60 Hz AC 220 240 V 50 60 Hz AC 220 240 V 50 60 Hz Power consumption 600 W 1000 W 1000 W Fuse 3 15 A 250 V slow blow 5 20 mm 5 0...

Page 22: ...rs one core plus shielding are typical representatives of the unbalanced transmission One conductor is ground and shielding while the signal is trans mitted through the core Unbalanced transmission is...

Page 23: ...g signal is completely neutralized The result is a pure signal without any noise inter ference 1 Signal 2 Ground shielding 1 Signal in phase 2 Signal out of phase 3 Ground 1 4 TS phone plug mono unbal...

Page 24: ...Signal left 2 Signal right 3 Ground 1 Ground shielding 2 Signal in phase 3 Signal out of phase 1 4 TRS phone plug stereo unbalanced XLR plug balanced Plug and connection assignments active subwoofer 2...

Page 25: ...1 Ground shielding 2 Signal 3 Bridged to pin 1 1 Signal 1 in phase 1 Signal 1 out of phase XLR plug unbalanced NL4 connections Plug and connection assignments CL 112 CL 115 CL 118 Sub MKII 25...

Page 26: ...ease follow the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste Dis...

Page 27: ......

Page 28: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...