User Manual of TI10 Series Variable Frequency Drive
- 27 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
(relative value)
14: torque command
P13.03
AO output bias -100.0%~100.0%
0.0%
0x1303
○
P13.04
AO output gain -2.000~2.000
1.000
0x1304
○
P13.05
AO output
filtering time
0.000s~10.000s
0.0s
0x1305
○
P20 Operating Keyboard Setting Parameters
P20.00
Password
setting
00000~65535
00000
0x2000
○
P20.01
LCD
brightness
control
10%~100%
80%
0x2001
●
P20.02
LCD language
selection
0: Chinese
1: English
0
0x2002
●
P20.03
Function code
modification
protection
0: all function codes can
be modified
1: only P20.00 and
P20.03 are allowed to
be modified
0
0x2003
●
P20.04
Function code
initialization
0: no operation
1: restore factory
parameters (no motor
parameters)
2: restore factory
parameters (including
motor parameters)
3: clear fault record
information (reserved)
0
0x2004
●
P20.05
Copy of
parameters
0: no operation
1: parameter uploading
2: parameter
downloading (no motor
parameters)
3: parameter
downloading (including
motor parameters)
0
0x2005
●
Summary of Contents for TI10 Series
Page 1: ...THINK DRIVES THE WORLD TI10SeriesVFD UserManual...
Page 7: ......