User Manual of TI10 Series Variable Frequency Drive
- 10 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
P01.03
Reverse
control
selection
0: allow reverse rotation
1: forbid reverse
rotation
0
0x0103
●
P01.04
Forward/Rever
s-e rotation
dead-zone
time
0.0s~3600.0s
0.0s
0x0104
●
P01.05
Selection of
starting mode
0: start from start
frequency
1: speed search starting
0
0x0105
●
P01.06
Starting
frequency
setting
0.00Hz~upper limit
frequency
0.50Hz
0x0106
●
P01.07
Hold time of
start frequency
0.0s~3600.0s
0.0s
0x0107
●
P01.08
Starting DC
brake
current/pre-ex
citation current
0.0%~100.0%
50.0%
0x0108
●
P01.09
Starting DC
braking
time/pre-excita
tion time
0.00s~30.00s
0.00s: Indicate that
starting DC brake is
invalid
0.00s
0x0109
●
P01.10
Selection of
stop mode
0: slow down and stop
1: free stop
0
0x010A
●
P01.11
Starting
frequency of
stop DC brake
0.00Hz~upper limit
frequency
0.50Hz
0x010B
●
P01.12
Stop DC brake
current
0.0%~100.0%
50.0%
0x010C
●
P01.13
Stop DC
braking time
0.00s~30.00s
0.00s:0.00s: indicate
that the stop DC brake
is invalid
0.00s
0x010D
●
P02 acceleration and deceleration parameters
P02.00
Acceleration
time 1
0.1s~6000.0s
Model
determination
0x0200
○