Thinget XC3 Series Installation Manual Download Page 1

THINGET

 

XC3 Series Programmable Controller

  

Installation Guide 

                                      Functions 

-

Dry and no dew                                                               - Insulate voltage: Up to DC 500V  

-Fr from corrosive gases and dusts                                   - Anti noise: 1000 V 1uS pulse per minute 
-Don’t install he unit in areas subject to                           -Ambient temperature: 0~60 C 
Liquid chemicals 

                                                     -Ambient humidity: 5~95% (no dew) 

Wiring                                                                              

-COM1: RS232, connect with host machine, HMI program or debug 

-Far from the high voltage, power supply or                    -COM2: RS232/RS485, connect with network or aptitude instrument 
Cable with high current                                                    -COM3: BD board COM port RS232/RS485 
-Never over voltage, make sure the polarity of                -Installation:can use M3 screw to fix or install directly on 

DIN46277 

    

Power supply is correct                                                    -Grounding: The third type grounding (cant public ground with strong  
 

                                                                                                             power system) 

Power Specification 

-to avoid voltage decrease please use cable thicker than 
2mm

 

- Even appear power cut within 10ms; PLC can still go 
on working. But if long time power cut or abnormal 
power decrease, PLC will stop working, output will 
also appear OFF status, when recover power supply, the 
PLC will auto to work. 
- Connect the grounding terminals of basic units and 
extend modules together, then ground. 

 

 

       Output Specification                                           Input Specification 

 

Terminal arrangement

  

 

                                                                                                             1-Input Terminals      2- BD expansion 
                                                                                                             3-Input Label             4-COM port 
 

                             5-COM port               6-COM port's cover board  

 

           

7-Output label            8-Output terminals 

 

 

9-Screws                   10-Input indicate LED 

 

 

11-Extension port                                  

 

                             12-Programming status indicate LED  

 

                             13-Output indicate LED 

 
  
 

Rated Voltage 

AC 100V~240V 

Voltage allow bound 

AC 90V~265V 

Rated frequency 

50/60 Hz 

Allow momentary  
power-cut time 

Interrupt time<0.5AC 
cycle,alternation>1sec 

Impact current 

Max 40A 5ms below/AC100V 
Max 60A 5ms below/AC200V 

Max power consumption  12W 
Power for sensor use 

24V DC   max400mA 

Transistor 
Output 

Relay output 

Items 

Below DC5~30V 

Below 
AC250V,DC30V 

Interior power 

Optical coupling 
 insulation 

Mechanism 
insulation 

Circuit insulation 

Indicate lamp LED 

Action denote 

0.8A 

3A 

Resistance 
load 

12W/DC24v 

80VA 

Inductive 
load 

1.5W/DC24V 

100W 

Lamp load 

 
Max 
Load 

DC5V    2mA 

Mini load 

Below 0.2ms 

10ms 

OFF to 
ON 

Below 0.2ms 

10ms 

ON to 
OFF 

 
Response 
time 

DC24V

Input signal's voltage

7mA/DC24V

Input signal's current

Up to 4.5mA

Input on current

Law than 1.5mA

Input off current

About 10ms

Input response time

Contact input or 
NPN
open collector 
transistor

 

Input signal's format

Photo-electricity 
coupling insulation

Circuit insulation

LED light when 
input ON

Input action's display