Figure 15: Dialogue “Reset yes”
Pressing the key “yes” carries out a restart of the Data logger.
Attention:
Switching off the supply without shutting down the Data logger can lead to damage
and failure of the network interface!
4.4 Loading Configurations from SD Card
If an SD card in the Data logger and contains a configuration file, the "Import" button is
displayed on the "SD card" dialog page. The configuration file must have the name
"Config.cfg" and be in the root directory of the SD card.
Note:
The dialog page "SD-Card" is always the last page.
Figure 16: Dialog page „SD card”
After pushing the “Import” button, the following dialog will be displayed.
1/14
Station : DLU1
Firmware : V01.01
Datum : 29.05.17
Zeit : 16:34:00
Sprache : deutsch
Reset data logger ?
yes
SD-Karte 14/14
Type : FAT32
Size : 8160MB
Export : all
Export
Import