ThermoWorks Thermapen Blue Operating Instructions Download Page 1

RADIO CERTIFICATIONS

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this 
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired 
operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est 
autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout 
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain 
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should 
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain 
maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique 
à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente 
(p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.

Operating Instructions

Made in the UK

Ref: 547-600  22.01.20

P-17-010-02-g

741 E. Utah Valley Dr., American Fork, UT 84003 

Ph: 801-756-7705    Fax: 801-756-8948 

thermoworks.com

Thermapen

®

 Blue

SPECIFICATIONS

–58 to 572°F (–49.9 to 299.9°C)
±0.7°F (±0.4°C) from –58 to 392°F (–49.9 to 199.9°C) 
otherwise ±1.8°F (±1.0°C)
2-3 sec. (reads to within 1°F of final temperature of an ice bath in 3 sec.)  
0.1° via remote device  
1 x AAA / 1000 hours
High-performance Type K thermocouple
Requires Bluetooth 4.1 or above
0.125 dia. x 4.3 L inches ( 3.3 dia. x 109 L mm)
with reduced tip to 0.06 dia. inches (1.5 dia. mm) 
IP67
–4 to 122°F (–20 to 50°C) 
1.97 H x 6.2 W x 0.75 D inches (50 H x 157 W x 19 D mm)
0.26 lbs (120g) 
NIST-traceable certificate included

Range

Accuracy

Response

Resolution

Battery

Sensor

Connection 

Probe

Water Resistance 

Environmental Range

Dimensions

Weight  

Calibration