The appliance, when operating, is hot to the touch, particularly the door of the combustion chamber: consequently, take
care not to touch any surface. Your appliance has obtained the CE marking. The product must not be used by children,
by persons with physical or mental impairments, by persons who are not familiar with the instructions for use and
maintenance of the product (the instructions are found in this use and maintenance booklet). During the heating and
cooling stages the appliance is exposed to considerable thermal expansions that can cause light expansion sounds. This
is a normal process and is not a defect of the product.
ATTENTION: while the machine is operating the door must remain firmly closed and airtight. While the appliance is in
operation the smoke exhaust pipes can reach extremely high temperatures: do not touch them! It is strictly forbidden to
use any type of liquid or gaseous fuel to light the appliance. Do not place non-heat resistant or inflammable or combustible
objects in the vicinity of the appliance: keep them at a suitable distance. Do not place wet clothing to dry on the appliance.
When using a clothes horse, keep at a suitable distance. The first time the appliance is started up the surface paint will
complete its drying process so you may perceive a light paint smell. It is recommended to ventilate the room until the
paint has completely dried.
5.1 LIGHTING
Before using the appliance check that all the movable parts are correctly fitted. Also remove any labels and stickers from
the glass to avoid that permanent traces remain on the surfaces. Also, check that the connection to the flue outlet has
been made correctly.
To startup the stove proceed as follows:
1)
Open the Smoke Bypass Device (C) by pulling it up with the special handle provided.
2)
Open the primary air (A) and the secondary air (B) completely by pushing the two levers outwards (see figure above).
3)
Open the firebox door (D) with the special handle, place some kindling in the firebox and light it with paper or any other tinder
available on the market, then close the firebox door (D).
IT IS PROHIBITED TO USE ANY LIQUIDS OR GASES SUCH AS ALCOHOL, PETROL ETC.. TO LIGHT OR
REKINDLE THE FIRE.
4)
Do not leave the appliance unsupervised while the lighting process is still in progress (roughly 30 minutes to complete the
process) or whenever there are abundant burning embers present.
5)
Once the lighting process is completed close the Smoke Bypass Device (C) using the special handle by pushing downward.
5.2 REFUELLING
The stove is an intermittent combustion appliance so it requires refuelling. Once combustion is achieved inside the combustion
chamber and consequently there are embers present, proceed with the first fuel feed:
1) Open the Smoke Bypass Device (C) by pulling it upwards with the special handle.
2) Wait a few seconds then slowly open the firebox door to avoid smoke outpour and spread out the embers using the supplied
poker, as shown in Figure 1.