10 – ALARMS
The appliance is programmed to communicate 7 alarms.
ATTENTION:
The appearance of one of the alarms described below, does not necessarily imply a defect in the
product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to
guarantee maximum safety, greater reliability and high performance of the appliance .
The alarms are listed below:
This meassge appears when during the
WORK
stage the temperature of the smoke drops below a preset threshold: this means
that the appliance is shutting off due to lack of pellets. To reset the alarm the power to the appliance must be switched off then on
by turning the switch 0-1 located on the power panel.
It is mandatory to empty and clean the brazier
, and then to fill the pellet
tank before repeating the START phase. It could be that the screw feeder is completely empty, so the start up sequence may have
to be carried out twice.
This appears if, after the
START
sequence, the smoke has not reached a suitable temperature. To reset the alarm the power to the
appliance must be switched off then on by turning the switch 0-1 located on the power panel.
It is mandatory to empty and clean the brazier
before repeating the START phase: pellets emptied from the brazier must not be
fed into the tank.
This occurs when the smoke outlet is partially blocked. To reset the alarm the power to the appliance must be switched off then on
by turning the switch 0-1 located on the power panel.
Before restarting the appliance check for any irregularities such as blocked flue outlet, open firebox door.
Do not start up the appliance until the problem has been identified and solved
It is mandatory
to empty and clean the brazier
before repeating the START phase:
This appears when the water temperature in the appliance exceeds 95°C.
After having verified and solved
the causes for the
overtemperature, unscrew the plastic cover of the reset thermostat located on the back and press the button (the appliance can
only be reset when its temperature has dropped considerably). To
reset the alarm
the power to the appliance must be switched off
then on by turning the switch 0-1 located on the power panel.
It is mandatory
to empty and clean the brazier
before repeating the START phase:
Appears when the smoke thermocouple is damaged or absent. Contact the technical assistance service
Activates when the smoke suction unit revolution sensor detects a very slow rotation speed: check the flue pipes and the flue outlet.
If the problem persists contact the technical assistance service.
Trips when the smoke suction unit revolution sensor fails to detect any rotation. The smoke suction unit or the rotation sens or are
not working. Contact the technical assistance service.
ALARM S1 DISCONNECTED:
The optional sensor S1 is interrupted or disconnected.
ALARM S2 DISCONNECTED:
The optional sensor S2 is interrupted or disconnected.
ALARM S acs DISCONNECTED:
The optional sensor of domestic hot water (ACS) is interrupted or disconnected.
ALARM S t.a. DISCONNECTED:
The optional room sensor is interrupted or disconnected.