3.1 THE FUEL
The fuel for this appliance is ordinary wood billets with a moisture content between 10% and 20% and with a thermal value of
13,000 to 15,429 Kcal/kg. We recommend using beech or common hornbeam. If using wood with a lower moisture content or with a
higher thermal value, the heat produced by the stove will be greater.
The awareness and use of the right fuel are important aspects to be observed in order to ensure correct operation and long service
life of the appliance. To this end we recommend using only dry, well-seasoned wood. We recommend against using wet wood or
wood that has been seasoned for less than 18/20 months, as this could be the cause of malfunctions and the formation of tarry
deposits that could permanently blacken the walls of the combustion chamber.
We recommend using logs with a length of 250 mm (max recommended section Ø 80 mm) and loading a maximum of 3-4 logs.
MAXIMUM PERMITTED FUEL FEED: 4.5 kg
THE FUEL FEED INTERVALS MUST NOT BE LESS THAN 1 HR
.
LOADING A LARGER QUANTITY OF FUEL OR
LOADING SEVERAL TIMES IN AN HOUR EXPOSES THE APPLIANCE TO VERY HIGH TEMPERATURES. FOR
THIS REASON THE WARRANTY WILL NOT COVER ANY DAMAGE CAUSED BY PROLONGED EXPOSURE OF
THE APPLIANCE TO THESE TEMPERATURES.
The use of fuel that does not comply with the above specifications or the use of different substances or fuels
will immediately void the appliance warranty. The appliance must not be used as an incinerator, and it is
prohibited to use any liquid or gas fuel. Do not overload the stove with excessive quantities of fuel; adhere
strictly to the maximum declared consumption.
It is strictly prohibited to store combustible or inflammable material in the compartment under the oven. The
temperature inside can reach very high levels.
3.2 MAIN COMPONENTS
KEY
A
Top smoke exhaust
B
Starter
C
Cooktop
D
Feed door
E
Thermometer
– Water pressure gauge
F
Primary air control
G
Adjustment ring for rekindling the fire
H
Grate adjustment handle release
mechanism
I
Oven light switch (only F30)
L
Grate height adjustment handle
M
Under-oven compartment (only F30)
N
Oven (only F30)
O
Smoke deviator flap (only F30)
P
Scraper
Q
Riddling tool
R
Rear smoke exhaust
S
Main ash pan
T
Inspection cover
U
Secondary ash pan
V
Pump active indicator light
Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
Luca Dalla Via
19/03/2004
BOSKY SQUARE 30
Scala
Locazione file
Data
F
irm
a
Foglio
Note
Materiale
Prodotto
Sviluppo
Assemblaggio stufa
4/14
TEL. 0445-741310 - FAX 0445-741657
Via Grumolo, 4 - 36011 ARSIERO (Vicenza) - ITALY
S.p.A.
Spessore
Approv
.
D
at
a
appro
v
.
Formato
LIBRETTO ISTRUZIONI
Cod.
Disegnatore
Volume
Peso
Colore
Revisione
0.000 kg
0.00 mm^3
\\tr-dc01\DatiOffice\Reparti\Tecnico\DWG\Solid_edge\BOSKY_2017\BOSKY_2018_restyle_no_forno.asm
Descrizione
Revisione
Autore
Data
Descrizione
LAMIERA
Il fornitore è responsabile della corretta realizzazione del
particolare come indicano le viste di progetto; lo sviluppo
piano deve essere verificato ed eventualmente modificato dal
fornitore in funzione delle macchine di piegatura che
andranno a realizzare il particolare.
STAMPI E FUSIONI
É obbligo da parte del fornitore, prima di
realizzare qualsiasi attrezzatura, fornire a
THERMOROSSI S.p.A. i file
tridimensionali dei particolari definitivi
X
S
T
U
V