background image

REV-0

6.11

SECTION 6

© 2010 Thermoplan AG, Subject to change

Technical Manual

Text message

Reason / solution

ab. 

 

Drain tub

•  Excess water inside the chassis below the hydraulic unit has shorted out    
     the two pins located at the back of the chassis.

– 

Check machine for leaks

•  Eventually change hydraulic or mechanical module

ac. 

 

Overtime error

•  Coffee flow is too slow ( > 2 Min.)

– 

Check grind setting and weight according to parameters

•  Water flow blocked

– 

Check brew valve on hydraulic module

•  Eventually change hydraulic or mechanical module

User messages

Summary of Contents for BLACK&WHITE 3 FOX2

Page 1: ...REV 0 6 1 CTM CBTM SECTION 6 2010 Thermoplan AG Subject to change Technical Manual DISPLAY MESSAGES FOX2 ...

Page 2: ...10 Page REVISION Page REVISION Page REVISION 2010 Thermoplan AG Subject to change SECTION 6 Technical Manual X Changes in content corrections S New paging Overview modification Modification journal Revision Date Modifications Initials 0 2010 01 20 First edition new document SO 1 2 3 4 5 6 7 8 9 10 Document Display messages ...

Page 3: ...REV 0 6 3 SECTION 6 2010 Thermoplan AG Subject to change Technical Manual Index User messages Index 6 4 Picture messages 6 5 6 7 Text messages 6 8 6 11 ...

Page 4: ...it up n Please clean unit o Please rinse unit p Please add milk q Powder error r Cleaning break Inert tablet s Cleaning key missing Please insert t Cleaning Press cleaning key u Voltage high 109 v Voltage low 91 For the following text messages the picture Product out appears on the touchscreen Enter code 111111 to see the message w Flow error x Change water filter y Piston error z NTC aa Service r...

Page 5: ...wntime of the ma chine you have to rinse the machine before operating b Controll drawer and insert it correctly Control the entry Drawer available in the service menu system test c Push outlet up to remove the grounds drawer Empty it and put it back after wards To reset the counter auto matically wait for 5 seconds before reinserting ...

Page 6: ...change SECTION 6 Technical Manual User messages Picture messages Solution d Open the cover of the hopper and refill it with fresh coffee beans e Open refrigerator and refill milk con tainer with milk f Pull down the command desk and close it ...

Page 7: ... User messages Picture messages Solution g Empty the milk container reinsert it put the suction tube back inside h After the cleaning the machine enters the standby mode Press continue to go back to the product screen i A serious error occured Contact the service technician ...

Page 8: ...ft Fill hopper M2 right Bean hopper out of beans or hopper gate closed Behälter füllen oder verriegeln Bean hopper or grinder outlet is obstructed Remove bean hopper and clear obstruction Defective 24V piston motor Defective grinder motor or capacitor Toothed belt or pulley is loose check Change mechanic module m Bean hopper missing or command unit up Bean hopper or command unit not correctly moun...

Page 9: ...city in brew chamber Check the powder quantity and adjust the grinder finer Defective 24V piston motor Drive screw or brew chamber contaminated Change mechanic module r Cleaning break insert tablet Cleaning was interrupted power outage during cleaning Start daily cleaning again s Cleaning key missing Please insert Cleaning key is not correctly mounted Insert cleaning key and turn it 90 clockwise D...

Page 10: ...sure on machine Check water pressure Change hydraulic module x Change filter Water filter is saturated Dispensing of products still possible Change water filter Reset counter y Piston Error Obsturcted 24V piston motor Check brew chamber and shaft for contamination or obstruction 24V piston motor has no impulse 24V piston motor has no 24VDC Change mechanical module z NTC Coffeeboiler open CPU does ...

Page 11: ...lic unit has shorted out the two pins located at the back of the chassis Check machine for leaks Eventually change hydraulic or mechanical module ac Overtime error Coffee flow is too slow 2 Min Check grind setting and weight according to parameters Water flow blocked Check brew valve on hydraulic module Eventually change hydraulic or mechanical module User messages ...