background image

INSTALLATION INSTRUCTIONS

GURU® DL 2.1

353 Ivyland Road • Warminster, PA 18974-2205 • Phone: 1-877-379-8258 • www.ThermOmegaTech.com

Before installing GURU® Plug, remove nose seal protector from cartridge.

1. Select locations for 

GURU® PLUGS

: These should be at the lowest positions possible on the system to be freeze 

protected and should be accessible for future re-arming.

2. Apply pipe thread sealant (Loctite 567 or equal) to the external threads on Hex body noting to leave leading thread 

bare so as not to contaminate the system.

3. Install the 

GURU® PLUG 

(tightening the hex body to 80 ft-lbs) with its cartridge facing down or at a 45° angle (as 

shown) for best accessibility. (Make sure lanyard is placed over paint mask and not between paint mask and cartridge 

tip. Paint mask must be cupped toward cartridge tip.) Do not remove paint mask (cover) on cartridge. 

Do not cut lanyard!

4. GURU® PLUG

 must be installed with a 2.75 in (69.85 mm) minimum operating clearance to allow cartridge to pop out.

5. Cartridge can be removed by pushing in and twisting counter-clockwise (no tools required) and re-installed by pushing 

in and twisting clockwise.

6. Under freezing conditions, cartridge may be re-installed after reheating. 

IMPORTANT: To operate properly in extreme conditions, the GURU®  

assembly must be dry. If the actuator nose seal leaks or drips, replace 

hex nut and cartridge immediately.

CAUTION: When re-arming GURU® always melt any ice formations from 

cartridge and inside of hex body prior to installing GURU® PLUG Cartridge 

to prevent seal damage.

NOTE: Cartridge and inside of hex body must be dry before assembly.

 

7. Preferred method of testing: 

GURU® PLUG

 must be removed from 

cooling system for proper testing. Horizontally place the assembly on a 

flat surface. Using a can of freeze spray (available through most home-

building supply stores or specialty suppliers) intermittently spray the 

actuator nose to keep a layer of frost on the metal surface. Cartridge 

should pop within one minute. If not, replace entire unit. Warm the cartridge before reinstalling.

To remove GURU® PLUG CARTRIDGE for service or warming*:

Push cartridge in and twist to the left (counter-clockwise) until it stops. Cartridge 

will pop out. Remove loop of lanyard cable from 

GURU® Cartridge

.

To reinstall GURU® PLUG CARTRIDGE*:

Make sure 

GURU® Cartridge

 is warmed to 55°F or higher. Replace loop of lanyard 

in groove of cartridge. Make sure lanyard is placed over paint mask and not be-

tween paint mask and cartridge tip. Paint mask must be cupped toward cartridge 

tip. Push cartridge in and turn to the right until locked. Do not remove paint mask 

(cover) on cartridge.

Make sure the Hex Nut seat is cleaned before reinserting. You can wipe it with an 

alcohol wipe or equal (lint-free) wipe.

*Prior to filling system with cold water, warm cartridge and place the GURU® 

Flag and Clip tool (shown at right: part number 04-052) in the slotted actuator to 

prevent cartridge from releasing. This will provide a visual indication that a GURU® 

cartridge is disabled. Do not use if you do not plan to immediately operate  

locomotive.

HEX BODY

CARTRIDGE TIP

BALL BEARINGS (3)

SLOTTED ACTUATOR

LOCKING
SLOTS (3)

Reviews: