Installing
the thermostat
Carefully separate the front half of the thermostat from the back plate by placing a small flat head
terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the cable connector which is plugged into the front half of the thermostat.
Place the thermostat front half somewhere safe.
Follow the Wiring Diagram to connect the floor heating cold leads, remote temperature sensor and
electrical supply to the appropriate terminals.
Screw the thermostat back plate on to the flush box. Re-connect the thermostat cable and clip the two
halves together.
Technical data
Supply voltage
230 - 240VAC
Maximum Load
16A
IP Rating
IP30
Warranty
2 Years
Width
80mm
Height
120mm
Depth
45mm (27mm in wall)
Temp Range
5°C - 35°C
Floor Sensor
(Resistance at 25°C )
10Kohm
Orientation
Vertical
Setting the date and time
Press and the time will begin to flash. Use
to select the correct time
Press until the day begins to flash (Note: Monday is Day 1). Use
to select the correct day
Press to save the settings
Heating Modes
When the timer is on, press the to switch between manual and schedule modes.
Manual Mode
In manual mode press the
to set the desired temperature in the thermostat setting or ON/OF status in the timer setting.
Schedule Mode
In the schedule mode the timer will follow the heating schedule that is set.
By pressing the
arrows it will override the current programmed temperature until the next programmed period.
Alternating between the thermostat and timer settings
When the unit is turned on press and hold for about 5 seconds to switch between the thermostat (with temperature displaying) and the
timer (with ON or OF displaying).
Advanced Settings
To access the advanced settings, turn the timer off by pressing
Press to display setting 01. Use the
to adjust the settings
Press to cycle between setting 01 to 04. Press to save the settings
Menu
Description
Range
Default
01
Sensor Mode
A=Air Sensoring Only F=Floor Sensoring
AF=Air & Floor Sensoring
A= Air Sensoring Only
02
Max Floor Temp Limit
20°C - 40°C
40°C by default
03
5+2 or 7 day Programming
01= 5+2 day program 02 = 7 day program
01 = 5+2 day program
04
Screen saver
ON = activated OF = not activated
OF= not activated
Key Lock
To lock the key pad, press and hold the
for 5 seconds or until the
displays. To unlock press and hold the
until the
disappears.
TNTDP / TNTDPB Touchscreen Thermostat Installation & User Guide
1. Day indicator
2. Key lock icon
3. Schedule mode icon
4. Manual mode icon
5. Temperature indicator
6. Confirm settings
7. Program button
8. Mode button
9. Power button
10. Air/Floor sensoring mode
11. Up & down arrows
12. Program period
13. Time
User Interface