Installing

 

the thermostat

 

Carefully separate the front half of the thermostat from the back plate by placing a small flat head 
terminal driver into the slots on the bottom face of the thermostat. 
Carefully unplug the cable connector which is plugged into the front half of the thermostat. 

Place the thermostat front half somewhere safe. 
Follow the Wiring Diagram to connect the floor heating cold leads, remote temperature sensor and 
electrical supply to the appropriate terminals. 

Screw the thermostat back plate on to the flush box. Re-connect the thermostat cable and clip the two 

halves together. 

 

Technical data 

Supply voltage  

 

230 - 240VAC  

Maximum Load   

16A 

IP Rating  

 

IP30 

Warranty  

 

2 Years  

Width   

 

80mm 

Height   

 

120mm 

Depth   

 

45mm (27mm in wall) 

Temp Range 

 

5°C - 35°C 

Floor Sensor 

(Resistance at 25°C )

 

10Kohm 

Orientation 

 

Vertical 

 
Setting the date and time

   

Press   and the time will begin to flash. Use 

 to select the correct time  

Press   until the day begins to flash (Note: Monday is Day 1). Use 

 to select the correct day 

Press   to save the settings 

 

Heating Modes 

When the timer is on, press the   to switch between manual and schedule modes.  

Manual Mode   
In manual mode press the 

 to set the desired temperature in the thermostat setting or ON/OF status in the timer setting.  

Schedule Mode   
In the schedule mode the timer will follow the heating schedule that is set. 
By pressing the 

arrows it will override the current programmed temperature until the next programmed period. 

 

Alternating between the thermostat and timer settings 

When the unit is turned on press and hold   for about 5 seconds to switch between the thermostat (with temperature displaying) and the 

timer (with ON or OF displaying). 
 

Advanced Settings

 

 

To access the advanced settings, turn the timer off by pressing 

  

Press   to display setting 01. Use the 

to adjust the settings 

Press   to cycle between setting 01 to 04. Press   to save the settings  
 

Menu 

Description 

Range 

Default 

01 

Sensor Mode 

A=Air Sensoring Only    F=Floor Sensoring 

AF=Air & Floor Sensoring 

A= Air Sensoring Only 

 

02 

Max Floor Temp Limit 

20°C - 40°C 

40°C by default 

03 

5+2 or 7 day Programming 

01= 5+2 day program    02 = 7 day program 

01 = 5+2 day program 

04 

Screen saver  

ON = activated    OF = not activated 

OF= not activated 

 

Key Lock 

To lock the key pad, press and hold the 

 for 5 seconds or until the 

 displays. To unlock press and hold the 

 until the 

 

disappears. 

    

TNTDP / TNTDPB Touchscreen Thermostat Installation & User Guide  

1. Day indicator 
2. Key lock icon 
3. Schedule mode icon 
4. Manual mode icon 
5. Temperature indicator 
6. Confirm settings 
7. Program button 
8. Mode button 
9. Power button 
10. Air/Floor sensoring mode 
11. Up & down arrows 
12. Program period 
13. Time 