![ThermoFLUX Pelling 100 User And Maintenance Manual Download Page 32](http://html1.mh-extra.com/html/thermoflux/pelling-100/pelling-100_user-and-maintenance-manual_1105654032.webp)
PELLING
32
To activate the option of cleaning the boiler, press the
SET
button, then press the buttons
5
or
6
to select the menu item
MENU 11-BOILER CLEANING.
By pressing the
SET
button, the fan is activated and operates at a maximum power of 250
seconds.
(*in older models, boiler cleaning is at
MENU 10
)
During the cleaning, it is necessary to opet the upper door of the boiler and clean all heat
exchange tubes with the metal cleaner (delivered with boiler).
6.3
Monthly cleaning
Cleaning of flue chamber
Power off boiler, disconnect boiler from power supply.
1.
Turn off boiler and wait for cooling.
2.
Unscrew the nuts on the back of flue chamber (picture below).
3.
Remove metal plate.
4.
Clean the content from the chamber into fireproof container.
5.
Place removed plate back to position and all nuts should be tighten back.