Minitherm -
If temperature rises above set temperature by 3 °C, stove will be shut down
automatically and on display will be written
WAIT COOLING
.
When temperature in the stove decreases for 2 °C below set temp. regulation will
start process of ignition again.
6.6
Cleaning of FIRE-POT
During its work stove has set timer for cleaning of combustion basket
(fire-pot) after certain time. This phase is shown on display and work of
the stove is set to lower power,and suction fan is working on maximun
for certain period of time as set in the factory.
When cleaning phase is finished, stove will continue to work and power will be
set on power choosen before.