Minitherm AQUA
27
5.3.3
LANGUAGE OPTIONS
Language settings are adjusted by pressing the
SET
button,and after that by pressing
of button
5
or
6
we choose option
MENU 03-LANGUAGE
. By pressing of the
SET
button language menu is opened (italian,english,german,french, croatian...) in which
we can choose desired language by pressing button
1
or
2
.
When desired language is choosen, confirmation is to be done by pressing button
SET
.
Returning back is done by pressing button
4
(
ON/OFF
)
5.3.4
STAND BY mode
STAND
BY
is used in two ways..
In the case that stove shuts down because desired temperature is reached
(set ON ),
In the case that stove modulates when desired temperature is reached (set
OFF
).
Function
STAND BY
can be set
ON
or
OFF
on following way:
STAND BY
mode is activated by pressing button
SET
, and afterwards by pressing
buttons
5
and
6
we choose desired item in the
MENU 04 – STAND BY MODE
. By
pressing
SET
we are opening options
ON
or
OFF
(choosed by pressing of buttons
1
or
2
, and confirmed by prissing of button
SET
).
5.3.4.1
STAND BY mode with installed sensor for air temperature
Connection for room thermostat is delivered overbridged, which means that
contact is closed.
1.
FUNCTION STAND-BY SET ON
In the case that function
STAND-BY
is activated (
ON
), stove will shut down when
desired temperature is reached and above by
2
degrees
C
, and after
2
minutes of time
pause (set in factory)
TON-WAITING COOLING
is displayed. If temperature do not
decrease below set temperature during 4 (four) minutes, on display is written
TON-
REQUEST WAITING
. When temperature of the air in stove is below set temperature
by
2
degrees
C
, stove will start again with ignition mode and it will work on set power.
2.
FUNCTION STAND-BY SET OFF
In the case that function
STAND BY
is not activated (
OFF
), and that connection for
the room thermostat is not overbridged, stove will always work in power
1
no matter
which power is set. In the case that function
STAND BY
is not activated (
OFF
), and
connection for room thermostat is overbridged (set in the factory) stove will work in
the power chosen by the user, and when desired temperature is reached will go into
modulation mode. Stove will shut down only if the temperature in the stove is 80
degrees
C
, and will start again when temperature drops down below desired
temperature.
Summary of Contents for Minitherm AQUA
Page 2: ...2...
Page 3: ...3...
Page 18: ...Minitherm AQUA 18 4 3 Hydraulic schemes for connection...
Page 23: ...Minitherm AQUA 23...
Page 24: ...Minitherm AQUA 24 5 3 1 Clock adjustments Clock adjustments can be done on following way...
Page 26: ...Minitherm AQUA 26 Flow chart 2 Flow chart 3 Flow chart 4...
Page 38: ...Minitherm AQUA 38 BLACK OUT The stove is out of power Reset alarm and start again...
Page 41: ...Minitherm AQUA 41 11 EU Label...
Page 42: ...Minitherm AQUA 42...
Page 43: ...Minitherm AQUA 43...