Bio Energy series
40.020.953 - rev.
05 - 2015
21
English
4
USE
4.1
During operation
4.2
Switching off
Switch off heating:
1. Switch the rocker switch to "0".
The fuel pump stops running.
The control light turns off.
5
MAINTENANCE
5.1
Maintenance table
Use the table in this manual to record the
maintenance after each winter.
/i
Hot
Do not touch the flue stack or blower
outlet! The flue stack and blower
outlet get hot during operation!
Caution
After switching off the heater it will
run for several minutes, until the fuel
on the burner dish is used up. In the
meantime the hot air fan and the
distributor fan keep running. These
fans cool the heater until it has
sufficiently cooled down (after 10 to
30 minutes).
Both fans will stop around the same
time.
Warning
Always clean the burner dish before
starting the heater.
Description
Period
Every
12
hours
Week-
ly
Month-
ly
Every
six
months
Annu-
ally
Every
two
years
Clean the burner dish.
X
Drain (water of) condensation from the
fuel tank, when the vegetable oil or
biodiesel contains water.
X
Clean the combustion chamber.
X
3. Switch the rocker switch to "2", see fig. 5
(E). The red control light is on, see fig. 5
(C).
3.4
Start up
1. Switch the rocker switch to "1", see fig. 5
(E).
When the burner dish has reached the
right temperature, the fuel pump starts
running and the control light is on.
2. During the first 20 - 30 minutes the fuel
pump should have a low capacity. The
yellow control light is on, see fig. 5 (A).
Summary of Contents for Bio Energy 2
Page 1: ...40 020 953 rev 05 2015...
Page 71: ...Bio Energy series 40 020 953 rev 05 2015 71 p 1 1 1 1 2 2 A B C D 1 3...
Page 72: ...72 40 020 953 rev 05 2015 Bio Energy series P 1 4 2 2 2 150 900 450 20 C...
Page 75: ...Bio Energy series 40 020 953 rev 05 2015 75 p 10 11 4 3 4 1 1 1 5 E 2 2 20 30 5 3 3 2 5 E 5 C...
Page 76: ...76 40 020 953 rev 05 2015 Bio Energy series P 4 4 1 4 2 1 0 5 5 1 i 10 30 12 X X X...
Page 77: ...Bio Energy series 40 020 953 rev 05 2015 77 p X X X 4 I X X X X X 8 2 mmwk X X X 12...
Page 81: ...Bio Energy series 40 020 953 rev 05 2015 81 p i 1 2 1 5 3 500 C 4 5 6...
Page 82: ...82 40 020 953 rev 05 2015 Bio Energy series P 7 3 8 9 3 4 10 11 12...
Page 83: ...Bio Energy series 40 020 953 rev 05 2015 83 p 13 5 3 9 12 13 14 15...
Page 84: ...84 40 020 953 rev 05 2015 Bio Energy series P 7 8 16 2 11 12 13 14...