EPD/HB/40521/000
ISSUE 5
EPD TECHNICAL HANDBOOK
Page 74
Counts Module
Code
Text as displayed by
EasyEPD2
EPD Action
Recommended
Customer
Action
Remarks
081
Unexpected Texas chip
reset (Battery Low but no
Batt Low Status)
Reset unit.
Return to
supplier if
recurs.
No Longer Used
082
Consecutive Drop (more
than 45 seconds)
No Longer Used
083
Counts not latched yet
no drop occurred
Reset into
comms
mode only —
counts
processing
disabled.
Return to
supplier
ASIC or interface to ASIC
may be faulty.
The only reason to not-latch
the counts would be that a
knock has occurred.
084
Counts Processing time
inconsistent
Reset
Reset unit.
Return to
supplier if
recurs.
Unlikely to occur unless
clock overflows. This is not
possible unless clock is
written with new value or
incremented at wrong rate.
085
Count too large (HG or
SG > 300,000) or (FB or
BC > 26,000)
Reset
- Ditto -
This fault can occur by
inputting a very large number
of counts ( only
possible under test
conditions or severe
interference).
086
Detector threshold load
failed
Reset into
comms
mode only —
counts
processing
disabled.
Reset unit.
Return to
supplier if
recurs.
Texas chip or associated
circuits may be faulty.
087
A calibration value is out
of range
Counts
processing
disabled
Return to
supplier
Display will indicate dashes,
but error code can be
extracted from error log.
An error status bit is also
set.
This fault will be picked up
on power-up, writing cal.
factors or thresholds, or
switching from OFF to ON
mode.
088
Abuse alarm (more than
45 consecutive seconds
of knocks)
None-
continues
normal
processing
Clear with
EasyEPD.
Return to
supplier if
recurs when
unit not
knocked.
Check knock detector
Summary of Contents for EPD Mk2
Page 6: ......
Page 10: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page xii ...
Page 14: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 4 This page is intentionally blank ...
Page 25: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 15 ...
Page 51: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 41 This page intentionally blank ...
Page 52: ......
Page 57: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 47 Figure 4 1 EPD Dimensions ...
Page 86: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 76 This page is intentionally blank ...
Page 103: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 93 This page is intentionally blank ...
Page 104: ......
Page 110: ...EPD HB 40521 000 ISSUE 5 EPD TECHNICAL HANDBOOK Page 100 This page intentionally blank ...
Page 112: ...EPD FAULT LOG FORM HB40521 ...