Summary of Contents for M79700

Page 1: ...9 9 10 ...

Page 2: ...tallation 5 Operation 6 Setting the Speed 6 Setting the Pitch 6 Setting the Timer 6 Operating Tips 7 Maintenance and Servicing 8 Timer Verification 8 Adjusting the Calibration of the Speed Control 8 Disassembling the Slow Speed Variable Speed Platform Rocker 9 Troubleshooting 10 Exploded View 11 Replacement Parts 12 Ordering Procedures 13 One Year Limited Warranty 14 ...

Page 3: ...d electrical shock always 1 Use a properly grounded electrical outlet of correct voltage and current handling capacity 2 Disconnect from the power supply prior to maintenance and servicing To avoid personal injury 1 Do not use in the presence of flammable or combustible materials fire or explosion may result This device contains components which may ignite such materials 2 Use appropriate hand eye...

Page 4: ...Thermo Fisher Scientific Robert Bosch Strasse 1 D 63505 Langenselbold Germany ...

Page 5: ... Remove your Platform Vari Mix Rocker from the carton Inspect to ensure that the unit has not been damaged during shipment Set the rocker on a flat stable surface and plug into an appropriate outlet Remove the white silicone rubber top from the protective plastic packaging and place the top on the metal platform Set the power toggle switch into the ON position The green power switch will illuminat...

Page 6: ...ovided 2 hrs for 60 Hz models 3 hrs for 50 Hz models Carefully observe the timer reference scale The timer reference scale is laid out in 10 minute incre ments with 30 minute 1 hour 90 minute and 2 hour posi tions noted The outer perimeter scale is referenced for 120 240 volt 60 Hertz timer motor operation The inner ref erence scale is for 120 240 volt 50 Hertz timer motor oper ation It is necessa...

Page 7: ...s removable Lift one corner to remove top The top must remain clean to maintain its friction gripping quality Wash with soap and water dry and reinstall 3 It is recommended that partial loads be centered on top to evenly distribute weight for longer life 4 When the Platform Vari Mix Rocker is sued within an incubator the incubator temperature must be stabilized with the rocker on as the motor gene...

Page 8: ...3 3 Locate the calibration potentiometer on the back panel Remove the cap Insert a screwdriver and turn the screwdriver clockwise to increase the rpm and counterclockwise to decrease the rpm The maximum speed correction is 2 4 rpm If more adjustment is necessary contact customer service at 800 553 0039 Your Platform Vari Mix Rocker will operate within the speci fied operating range of 5 30 rpm und...

Page 9: ...ponents in the lower case are easily accessible for replacement and removal However some assembly tips are given as fol lows a Remove the four Phillips head screws holding the motor to the mounting plate to remove motor b Removing the timer control knob requires resetting the red line indicator to the point where the time elapses and tightening the set screws Check timing with a calibrated elapsed...

Page 10: ...ive loading Reduce load weight Calibration changed Recalibrate unit Timer does not function Defective timer Replace timer Knob setscrew loose Tighten setscrew and recalibrate Timer does not turn off after Defective timer Replace timer elapsed time has expired Timer inaccurate Knob slipped on shaft Replace knob or tighten setscrew User reading wrong Hz scale Use the 60 Hz scale for 60 Hz power supp...

Page 11: ...11 Exploded View ...

Page 12: ... CRM2030X1 Cord set 5120 0016 Fuse on PCB MTX94 DC motor PC797X2A Printed circuit board all components mounted PT717X1 Silicon platform cover White RSX322 Calibration port on rear of unit RSX264 Potentiometer speed control SWX135 Switch 100 120V SWX136 Switch 240V TM797X1A Timer 380 570 00 Strain Relief All models FZX49 Fuse Accessories Part Number Description AY797X1 Double Tier Platform Replacem...

Page 13: ...800 943 2006 or 800 926 0505 ...

Page 14: ...0 Italy 39 02 02 95059 434 254 375 Netherlands 31 76 571 4440 Nordic Baltic countries 358 9 329 100 Russia CIS 7 812 703 42 15 Spain Portugal 34 93 223 09 18 Switzerland 41 44 454 12 12 UK Ireland 44 870 609 9203 Asia China 86 21 6865 4588 or 86 10 8419 3588 India toll free 1800 22 8374 India 91 22 6716 2200 Japan 81 45 453 9220 Other Asian countries 852 2885 4613 Countries not listed 49 6184 90 6...