8
Cleaning and Disinfection
Steri-Run Sterilization Routine
Thermo Scientific
Heracell Vios 160i / 250i CR
8-13
Completing Steri-Run
When all three phases have been completed, the
Steri-Run End
(
) dialog window is
displayed automatically. The sterilization routine must be stopped manually.
Figure 8-8.
To stop Steri-Run
• To stop Steri-Run:
• Press the
End
key.
• The system returns to the main menu.
Note
Opening door during Steri-Run sterilization:
If the door will be opened and closed again whilst Steri-Run sterilization is running, the routine
returns to a phase which will ensure a continuation without faults.
Note
Risk of burns! Avoid opening the door unless in case of an emergency.