background image

10  |   Emerald Bluetooth Enabled Wireless Remote Sensors

Compatible Sensors for Smart-Vue Pro Duo / Quatro Data Logger

Emerald Bluetooth Enabled Wireless 
Remote Sensors 

Smart-Vue Pro data loggers are equipped with Bluetooth low 
energy connectivity to use Emerald sensors as wireless 
remote sensors. Emerald sensors can have an integrated 
temperature sensor or an external Pt100 probe. This enables 
you to monitor and manage equipment in hard-to-access 
locations or where it is impractical to connect wired sensors 
to your Smart-Vue Pro data logger.

Wired and wireless remote sensors connected to a 
Smart-Vue Pro data logger offer the same web application 
usage and functionality.

Figure 1. Smart-Vue Pro data logger with Emerald 

Wireless Remote Sensor (Integrated 

Temperature Sensor)

Figure 2. Emerald with external Pt100 sensor 

You can use any combination of wired or wireless remote 
sensors with your Smart-Vue Pro data loggers with up to two 
active wireless remote sensors on Smart-Vue Pro Duo or up 
to four on Smart-Vue Pro Quatro.

For the Smart-Vue Pro data logger to detect your nearby 
Emerald wireless remote sensor, you must first activate 
Bluetooth on the sensor as described below. The Smart-Vue 
Pro data logger cannot discover a wireless remote sensor if it 
is disabled or in standby mode.

Wireless Remote Sensor 

Calibration

It is important to calibrate the sensors on your Smart-Vue Pro 
data loggers to fine-tune the accuracy of readings. The 
calibration procedure for wireless remote sensors is typically 
handled by a qualified metrology laboratory which determines 
precise correction coefficients and loads them directly in the 
Emerald wireless remote sensor’s memory.

CAUTION: 

Emerald Bluetooth sensors must have 

firmware version 2.3.2 or higher to function as 
wireless remote sensors with Smart-Vue Pro data 
loggers as described in this chapter.

CAUTION: 

Calibration parameters are stored 

directly in Emerald sensors to adjust readings for 
maximum accuracy. Calibration parameters 
cannot be edited via the Smart-Vue Pro web 
application. 

Summary of Contents for Differential Pressure Sensor

Page 1: ...e Sensors for Smart Vue Pro Duo Quatro Data Logger Emerald Wireless Remote Sensor Triple CO2 Temperature and Humidity Sensor Differential Pressure Sensor Supplemental User Guide 331942H01 Revision B 1...

Page 2: ...med by qualified service personnel Material in this manual is for informational purposes only The contents and the product it describes are subject to change without notice Thermo Fisher Scientific ma...

Page 3: ...s Remote Sensors 10 Wireless Remote Sensor Calibration 10 Key Specifications 11 Inserting the Battery into your Emerald Sensor 11 Activating an Emerald Wireless Remote Sensor 11 Mounting your Emerald...

Page 4: ...Smart Sensor 22 Overview 22 Usage 22 Tube Placement 23 Key Specifications 24 Placement and Assembly 24 Velcro location on Extension box 25 Appendix 1 Troubleshooting 26 Appendix 2 Emerald Battery Life...

Page 5: ...ct s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to a person CAUTION This product contains two non rechargeable 3 6V lithium batteries Plugging the device into...

Page 6: ...TION Do not use this device in explosive or hazardous environments CAUTION Do not expose your device to any extreme environment where the temperature or humidity is high Such exposure could result in...

Page 7: ...and contact OCEASOFT technical services Battery Warning CAUTION This product contains a lithium battery Make sure you respect polarity when inserting batteries into OCEASOFT devices Reversing polarit...

Page 8: ...subject to the following two conditions 1 This device may not cause interference 4 Certifications and Compliance 2 This device must accept any interference including interference that may cause undes...

Page 9: ...is in compliance with the EU Directive 2011 65 EU Restriction of the Use of Certain Hazardous Substances in Electronic and Electrical Equipment and the amendment of EU 2015 863 Do not dispose of this...

Page 10: ...imum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropi...

Page 11: ...d other relevant provisions of the Waste Electrical and Electronic Equipment Directive 2012 19 EU WEEE Directive Environmental Protection RoHS Compliance Respect local regulations concerning disposal...

Page 12: ...potentially expose you to chemicals including lead which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov Respect local regulations concerning disp...

Page 13: ...remote sensor Triple CO2 Temperature and Humidity sensor Differential pressure sensor The focus in this document is mainly on physical hardware aspects of the Smart Sensors listed above Where to go f...

Page 14: ...s with up to two active wireless remote sensors on Smart Vue Pro Duo or up to four on Smart Vue Pro Quatro For the Smart Vue Pro data logger to detect your nearby Emerald wireless remote sensor you mu...

Page 15: ...remote sensor you must first activate the sensor as described here 1 Place the strong side of the magnet the side without the adhesive tape in the circular recess on the back of the Emerald sensor an...

Page 16: ...Adhesive Tape You may also choose to mount the Emerald sensor using the provided adhesive tape Note Clean the magnet before using the adhesive tape on it Using Wireless Remote Sensors with your Data L...

Page 17: ...o another Smart Vue Pro data logger cannot be paired 6 Tap the sensor and confirm the connection by tapping OK 7 Wait until pairing is complete which may take a few seconds Once pairing is successful...

Page 18: ...place damaged cables Wired sensors may be replaced at any time whether data logging is running or not You must ensure that the existing and replacement sensors are identical in type The process is com...

Page 19: ...y the Smart Vue Pro web application Wireless Remote Sensors in Smart Vue Pro Web Application This section provides additional information regarding the use of wireless remote sensors in the Smart Vue...

Page 20: ...data logger via the data logger menu displays the wireless remote sensor with the Bluetooth logo as shown here Figure 15 Wireless remote sensor shown on data logger Wireless Remote Sensor in the Senso...

Page 21: ...o and is displayed purely for future use Wireless Remote Sensor Battery Indication The wireless remote sensor battery percentage is shown under Smart Tracker Pro as below Figure 20 Wireless remote sen...

Page 22: ...inside the incubator Remove the CO2 temperature and humidity sensor from inside the incubator during decontamination procedures which may expose the sensor to damaging heat environment CAUTION Failure...

Page 23: ...90 RH non condensing for indoor use Contact your Thermo Fisher Scientific representative for details regarding sensor accuracy drift and calibration Placing the Sensor and Smart Vue Pro Data Logger Fo...

Page 24: ...cable into the Smart Sensor extension and the Smart Vue Pro data logger 2 this cable provides power to the Smart Vue Pro data logger Figure 27 Power connections for triple sensor unit 5 Connect the S...

Page 25: ...uting sensor cables avoid direct contact with or close proximity of sensor cabling with any high voltage wiring Cabling should be placed with no less than a minimum of 2 inches 50 mm distance from hig...

Page 26: ...placed outside the cleanroom so that people know it is safe to enter as shown in these two examples 1 High pressure cleanrooms such as vaccine and organ transplant laboratories in which the ambient pr...

Page 27: ...he display A common way to use this sensor is therefore to plug the tube onto the high connector and under normal conditions obtain positive values when monitoring high pressure cleanrooms and negativ...

Page 28: ...te or connector on the data logger 2 Clip the Smart Sensor extension firmly onto the bottom of the Smart Vue Pro data logger Figure 38 Slide the smart sensor extension onto Smart Vue Pro data logger 3...

Page 29: ...Compatible Sensors for Smart Vue Pro Duo Quatro Data Logger Differential Pressure Smart Sensor 25 Velcro location on Extension box Figure 39 Velcro location...

Page 30: ...in the Smart Vue Pro web application What should I do During pairing the Smart Vue Pro data logger downloads calibration parameters from the wireless remote sensor If wireless remote communication fa...

Page 31: ...e user tries to unpair the remote sensor which is in out of range from the Smart Vue Pro data logger a message is displayed on the Smart Vue Pro data logger to reset the remote sensor to finish unpair...

Page 32: ...a Logger Does the Emerald device send a low battery alert to the data logger Emerald low battery indication is not shown on Smart Vue Pro Duo Quatro data logger but Emerald low batery status level are...

Page 33: ...conditions Wireless remote communications Bluetooth connections consume battery power However it is worth noting that the Smart Vue Pro data logger reads Bluetooth advertising frames from the Emerald...

Page 34: ...thermofisher com WEEERoHS Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2012 19 EU in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE marcato col...

Page 35: ...e 33 2 2803 2180 Germany international 49 6184 90 6000 Germany national toll free 0800 1 536 376 Italy 32 02 95059 552 Netherlands 31 76 579 55 55 Nordic Baltic CIS countries 358 9 329 10200 Russia 7...

Reviews: