![Thermo Scientific DensityPRO NAI Series User Manual Download Page 174](http://html.mh-extra.com/html/thermo-scientific/densitypro-nai-series/densitypro-nai-series_user-manual_1105169174.webp)
Density Calculation
Slurry Material
C-16
DensityPRO User Manual
Thermo Scientific
Spv = percent by volume solids (%) calculated using
.
Qvs = Solids volumetric flow rate calculated using Equation 20.
100
∗
Equation 20
–
Carrier Volumetric Flow rate – The volumetric flow rate of the carrier flowing in
the slurry.
Qv = Volumetric flow rate of slurry in cubic centimeters per second; measured
by the gauge using an analog input.
Cpv = percent by volume carrier (%) calculated using
Qvc = Carrier volumetric flow rate calculated using Equation 21.
100
∗
Equation 21
–
Bulk Solids Flow rate (Reference
–
Temperature – The temperature measured by the temperature input.
–
Velocity – The velocity of the slurry
Qv = Volumetric flow rate of slurry in cubic centimeters per second; measured
by the gauge using an analog input.
L = Inside diameter of the pipe in centimeters.
V = Velocity of the slurry calculated using volumetric flow rate.
∗
4
Equation 22
–
Proppant – Reference