Summary of Contents for ALPHA COND 1000

Page 1: ...Alpha COND 1000 Controller Transmitter uS cm mS cm C...

Page 2: ...k ROSS Resolution SAOB SMART AVERAGING Smart CheK SMART STABILITY Stacked Star Navigator 21 Stat Face The Enhanced Lab ThermaSense Triode TRIUMpH Unbreakable pH Universal Access are trademarks of Ther...

Page 3: ...applications of the Alpha COND 1000 process controller transmitter If you have doubts in the use of the instrument please do not hesitate to contact the nearest Authorized Distributor Thermo Scientifi...

Page 4: ......

Page 5: ...of the instrument Before powering up the unit make sure that power source it is connected to is as specified in the top label Failure to do so may result in a permanent damage to the unit The unit has...

Page 6: ...9 5 2 1 How to enter and change parameters in Calibration mode 9 5 2 2 How to enter and change parameters in Advanced Setup mode 9 6 CALIBRATION MODE 11 6 1 Conductivity Calibration 11 7 ADVANCED SET...

Page 7: ...7 4 Selecting steady or pulse contact for the alarm relay 24 7 7 5 Wash contact if the relay 3 is set to Wash 25 7 7 6 Input Line Resistance Adjust 25 7 7 7 Reverting to factory default settings 25 7...

Page 8: ......

Page 9: ...second time delay adjustment on all relays minimise false alarms Separately adjustable high and low set point hysteresis dead bands prevents chattering of relays around the set points Selectable Filte...

Page 10: ...process assembly a final control element such as pump or valve and a chart recorder Power Mains 220 110 VAC Alpha CON1000 Controller Flow Assembly to Dosing Pumps Process Assembly with Electrode Char...

Page 11: ...lly separated from the power supply 3 1 Connection Diagram Signal Output Hold Input Alarm Relay 2 Relay 1 Power Mains Cond mA PE S PE AC N L 1 2 5 4 3 6 7 8 9 10 11 12 13 14 15 17 15 16 indicated cont...

Page 12: ...ld function switch terminal 1 5 Low set relay common 14 Hold function switch terminal 2 6 Low set relay working position NO 15 No connection 7 High set relay resting position NC 16 0 4 20 mA for ve co...

Page 13: ...itch between RELAY A and RELAY B in MANUAL relay operation mode 4 1 2 Display The LCD display features two numerical displays that show status messages and measured values for easy quick reference The...

Page 14: ...rameters can be viewed or changed by entering a security code See Section 5 2 for security code information 4 2 1 How to view operating parameters without access to change them a Press the ENTER key T...

Page 15: ...A Display Cal Ratio Hysteresis 2 Calib temp MTC Calibrate Pt100 Pick up delay contact 1 Dropout delay contact 2 Set Filter Function Select Load Factory Default Calibrate to Standard MIN MAX Function C...

Page 16: ...ectrode slope and offset values without changing them 1 Press the CAL key followed by the ENTER key without adjusting the security code leave code at 000 The upper display shows the condition of the p...

Page 17: ...or keys simultaneously escape to return to the Measurement mode NOTE To view not change the SETUP parameters push the ENTER key when the security code reads 000 5 2 1 1 Clearing the Calibration secur...

Page 18: ...lly reset the code To clear the Advanced Setup security code from the display 1 Press the ENTER key in the Measurement mode 2 Set to any security code not 11 or 22 and complete by pressing ENTER NOTE...

Page 19: ...n the solution to remove any trapped air bubbles Note The calibration standard should have a value that is between 20 to 100 of the range selected For example if the range in the controller is selecte...

Page 20: ...erature compensation the controller automatically changes from the preset process temperature to the calibration temperature After leaving the Calibration mode the controller switches back to process...

Page 21: ...anced Set up security code 22 2 Push the ENTER key Controller displays tc 3 Push ENTER key again and use or keys to select between Pur and Lin temperature coefficients 4 If Pur tC is be selected press...

Page 22: ...ode by pressing the and keys escape simultaneously 7 2 1 Setting Manual Temperature Compensation NOTE This parameter is blanked out when the controller is set for ATC operation For manual temperature...

Page 23: ...Set point 1 or Set point 2 sub function The alpha CON 1000 controller transmitter can operate in either one of the 10 different conductivity ranges see Section 12 2 Appendix 2 Measurement Ranges Avai...

Page 24: ...have set your set point 1 Lo at 100 0 S and your hysteresis limit value is at 20 S If your measured value undershoots the low set point of 100 0 S the controller s relay activates which in turn activa...

Page 25: ...ection 5 Proceed to 7 3 6 or return to Measurement mode by pressing the and keys simultaneously escape 7 3 6 Setting an off delay time lag You can set as time delay for each relay which stops the rela...

Page 26: ...sub function YP YP YP YP E L HOLD HOLD HOLD HOLD HOLD SETUP SETUP SETUP SETUP SETUP L c EE FF PLC PFC HOLD SETUP 7 4 1 Entering the Controller sub function 1 Enter Advanced Set up mode Push the ENTER...

Page 27: ...Ct limit value pickup on off control oFF controller off PLC pulse length control PFC pulse frequency control 4 Press the ENTER key to confirm your selection 5 Proceed to 7 4 3 or return to Measurement...

Page 28: ...listed in 7 4 3 7 4 4 and 7 4 5 are blanked out This mode lets you set the maximum pulse length or the maximum frequency at which the relay will operate 1 Follow directions in 7 4 1 to enter Controll...

Page 29: ...s the or keys to scroll until the upper display shows rng 3 Press the ENTER key The upper display shows the maximum measurement range while the lower display shows the Cell constant In the lower left...

Page 30: ...s until the upper display shows the output type 0 20 or 4 20 and the lower display shows out 3 Press the or keys to select your output type 0 20 or 4 20 mA 4 Press the ENTER key to confirm your select...

Page 31: ...nfigure the controller to suit your requirements 7 7 1 Entering the Configuration sub function 1 Enter Advanced Set up mode Push the ENTER key and scroll to Advanced Set up security code 22 Push the E...

Page 32: ...0 to 1999 seconds you want 4 Press the ENTER key to confirm your selection 5 Proceed to 7 7 4 or return to Measurement mode by pressing the and keys simultaneously escape 7 7 4 Selecting steady or pul...

Page 33: ...sistance 0 0 to 100 0 3 Press the or keys to input the value 4 Press the ENTER key to confirm your selection 5 Proceed to 7 7 7 or return to Measurement mode by pressing the and keys simultaneously es...

Page 34: ...ence is that the controller will revert back to Set up mode instead of Measurement mode after calibration is completed 7 8 1 Entering Calibration mode from Advanced Set up mode 1 Enter Advanced Set up...

Page 35: ...00 the lower display shows S Cd to prompt you to enter the Advanced Set up code 2 Press the or keys to scroll the upper display until it reads 22 3 Press the ENTER key The manual indicator by the RELA...

Page 36: ...ller 2 potential free change over contacts Switching voltage max 250 VAC Switching current max 3A Switching power max 600 VA Alarm Functions Function switchable Latching pulse Pickup delay 0 to 1999 s...

Page 37: ...result of abuse or misuse within the warranty period please return by freight pre paid and amendment will be made without any charge Our Customer Service Dept will determine if product problem is due...

Page 38: ...wer supply 12 1 Appendix 1 Jumper Positions Jumper Positions Internal to the controller JP 1 Selects the input voltage 220 VAC JP 2 Selects the input voltage 110 VAC JP 6 Selects the temperature senso...

Page 39: ...0 199 9 mS 0 1 mS 10 0 0 0 0 199 9 mS 0 1 mS 1 0 12 3 Appendix 3 Conductivity at Related Temperature Coefficients 25 C Substance Concentration wt Conductivity 10 4 S cm Conductivity Coefficient NaOH 5...

Page 40: ...53 2 27 Na2SO4 5 409 2 36 10 687 2 49 15 886 2 56 HCl 5 1969 1 58 10 3124 1 56 20 3463 1 54 30 662 1 52 40 5152 H2SO4 5 2085 1 21 10 3915 1 28 20 6527 1 45 40 6800 1 78 50 54055 1 93 60 3726 2 13 80 1...

Page 41: ...ppendix 4 Conductivity of Various Aqueous Solutions at 25 C Conductivity Resistivity Pure Water 0 05 uS cm 18 M cm Power Plant Boiler Water 0 05 1 uS cm 1 18 M cm Distilled Water 0 5 uS cm 2 M cm De i...

Page 42: ...IS BAND FORWARD DIRECTION REVERSE DIRECTION SP1 SP2 RELAY ON SP2 Set to HI mS The controller relay activates when the set point is reached In the reverse direction it does not de activate when the val...

Page 43: ...12 6 Appendix 6 General Instructions Concerning Controller Setting MIN Function MAX Function Xp 0 Xp 0 SP 1 SP 2 Xw Xw Yh 0 50 100 Control characteristic of P Controllers as limit value switch...

Page 44: ...Fax 978 232 6031 Europe P O Box 254 3860 AG Nijkerk Wallerstraat 125K 3862 CN Nijkerk Netherlands Tel 31 033 2463887 Fax 31 033 2460832 Asia Pacific Blk 55 Ayer Rajah Crescent 04 16 24 Singapore 13994...