background image

Operating Manual

0000848 

• 

Revision A

 

• 

October 2021

Thermo Scientific Digital Drybath

Summary of Contents for 88870001

Page 1: ...Operating Manual 0000848 Revision A October 2021 Thermo Scientific Digital Drybath ...

Page 2: ... be held liable for any damages direct or incidental arising out of or related to the use of this manual No part of this manual may be reproduced or transmitted in any form or by any means including photocopying recording or using information storage and retrieval systems for any purpose other than the purchaser s own use without the express written permission of the manufacturer Any other product...

Page 3: ...aration Work 8 Structure Diagram 8 Display Panel Diagram 8 Instructions for Buttons 8 Operation Guidance 9 Examination Before Startup 9 Startup 9 Setting Temperature and Heating Time 9 Start and Stop Instrument 10 Temperature Measurement and Calibration 10 Maintenance 11 Failure Analysis and Troubleshooting 12 Modular Block Accessories 13 Warranty 15 Frequently Asked Questions 16 ...

Page 4: ... 100 120 Vac TS Drybath Stdrd 1 blck 100 120 V 88870002 N A 100 120 Vac TS Drybath Stdrd 2 blck 100 120 V 88870003 N A 100 120 Vac TS Drybath Stdrd 4 blck 100 120 V N A 88870004 200 240 Vac TS Drybath Stdrd 1 blck 200 240 V N A 88870005 200 240 Vac TS Drybath Stdrd 2 blck 200 240 V N A 88870006 200 240 Vac TS Drybath Stdrd 4 blck 200 240 V ...

Page 5: ...s Before the instrument is connected to the AC power source the voltage of the power source should be the same with the required voltage of the instrument a deviation of 10 is allowed The rated load of the power socket should not be lower than the requirements of the instrument The power cord The instrument should use the power line cord attached to it If the power line is destroyed it must be rep...

Page 6: ...he mains supply Explanation of symbols Attention read user manual before use WARNING There is a sign of CAUTION HOT SURFACE ATTENTION SURFACE HOT on the instrument The metal part module near the sign should not be touched with any part of the body when the instrument is operating in a high temperature state or just finished operation to avoid burns Alternating Current Protective Conductor Terminal...

Page 7: ...eration and serum coagulation etc The characteristics of the product are as follows The digital display for control of the temperature Heat blocks help avoid possible contamination while containing the sample inside a tube The heat blocks are easy to replace clean and disinfect and are suitable for various tubes sizes Built in over temperature protection device warrants sample and user safety Temp...

Page 8: ...trument please make sure the working condition meets the above requirements Especially that the power line is reliably grounded Table 2 100 120 V NA Catalog Number 88870001 88870002 8887000303 Model Name Digital 1 block 100 120 V Digital 2 block 100 120 V Digital 4 block 100 120 V Temperature Range Ambient Temperature 5 C 130 C Ambient Temperature 25 C Temperature Uniformity 1 0 C 37 C Temperature...

Page 9: ...1 3 7 87 3 94 in 318 200 100 mm 12 5 7 87 3 94 in 450 200 100 mm 17 7 7 87 3 94 in Weight 2 9 kg 6 39 lbs 3 3 kg 7 28 lbs 4 7 kg 10 36 lbs Fuse Protector ø5 20 F 250 V 2 5 A F 250 V 2 5 A F 250 V 3 15 A CAUTION The instrument is only used for heating operation from low temperature to high temperature The European voltage models of this product meet all the applicable requirements of the European D...

Page 10: ... addressing these actions for safe recycling and disposal please follow all guidelines Safety Data Sheets SDS or regulations applicable to your country and region This product has materials and components that may be recycled or reused according to local guidelines and regulations Remove any batteries present before disposal Batteries battery packs and accumulators should not be disposed of as uns...

Page 11: ...o lift blocks Digital Display Warning Indicator Light Heating Indicator Light Setting or adjusting button Press the button to display present setting temperature and press the button again to display present time After the unit has reached set point and temperature is stable calibration can be set by pressing the button Under the status of setting press or to modify the flashing figure The instrum...

Page 12: ...press Stop 4 Set up Temperature a Press the SET CAL button The instrument is in the Temperature Setpoint mode with the display window showing the previous temperature set value and the left digit flashing b Press to increase or to decrease the flashing digit of the Setpoint c Press SHIFT to move the flashing right to the next digit d Repeat Steps 4b and 4c to complete Temperature setpoint selectio...

Page 13: ...he Display and independent measurements And check if the temperature gap is 0 2 C or not 5 If less than 0 2 C no calibration should be made 6 If more than 0 2 C calibrate the Temperature by these steps a Press and hold the SET CAL button The instrument is in the Temperature Calibration mode with the display window showing the measured temperature value and the left digit flashing b Press to increa...

Page 14: ...he holes so as to have good heat conduction If the surface of the instrument is polluted it can be cleaned with a slightly damp soft cloth Generally unit falls under protective system of IP20 pursuant to IEC 60529 WARNING When cleaning the instrument the power supply should be shut off and unplugged The instrument surface should be cleaned with a non corrosive cleaning agent ...

Page 15: ...lay window is not turned on after switching on power supply Power supply fails to be connected Check power supply and connect it Fuse burned out Replace fuse Damage of the switch Replace the switch Others Contact Thermo Fisher Scientific 2 Temperature display window shows 001 and the buzzer alarm in a di di sound Short circuit of sensor Check if the connecting line of sensor is damaged and replace...

Page 16: ... x 3 0 x 1 5 88870107 For 17 mm 18 mm test tubes 12 124 x 76 x 39 4 9 x 3 0 x 1 5 88870108 For 20 mm test tubes 8 124 x 76 x 39 4 9 x 3 0 x 1 5 88870109 For 25 mm test tubes 6 124 x 76 x 39 4 9 x 3 0 x 1 5 88870110 For 0 5 ml test tubes 40 124 x 76 x 39 4 9 x 3 0 x 1 5 88870111 For 96 well Elisa plate 1 124 x 76 x 39 4 9 x 3 0 x 1 5 88870112 For mixed size test tubes 32 holes for 6 mm test tubes 2...

Page 17: ...3 0 x 4 55 88870118 For 15 ml conical bottom test tubes 15 124 x 76 x 113 4 9 x 3 0 x 4 55 88870119 For 50 ml conical bottom test tubes 4 124 x 76 x 113 4 9 x 3 0 x 4 55 88870120 For 96 well Non skirted PCR plate 1 124 x 76 x 39 4 9 x 3 0 x 1 5 88870121 For 96 well half full skirted PCR plate 1 124 x 76 x 55 4 9 x 3 0 x 2 17 88870122 Temperature probe PT1000 stainless steel NA NA Dry bath blocks c...

Page 18: ...ese operation instructions and maintenance this product is warranted for 24 months against defective materials or workmanship The 24 month warranty period begins from the delivery date of this product For product quality or performance issues contact Thermo Fisher Scientific Customer Service ...

Page 19: ...doesn t hold the set temperature It will cool to ambient temp Q Would unit return to ambient temp A The unit will return to ambient temp Scenario 2 Suppose the unit is running a set program and there is power outage Once the power resumes Q Would unit restart automatically once power is restored A The instrument will automatically turn on Q Would unit resume the program from where it was left A It...

Page 20: ...nter thermofisher com WEEERoHS Conformità WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2012 19 EU in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE È marcato col seguente simbolo Thermo Fischer Scientific ha stipulato contratti con una o diverse società di riciclaggio smaltimento in ognuno degli Stati Membri Europei Questo prodotto verrà smaltito o rici...

Page 21: ...d let support thermofisher com Singapore Technical Support Team Service Hotmail is Service LPG ROA1 thermofisher com Thermo Fisher Scientific Inc 22 Alpha Rd Chelmsford MA 01824 USA Find out more at thermofisher com drybaths Australia 613 9757 4300 In Australia 1300 735 295 China 86 21 6865 4588 Germany 49 6184 90 6321 India 91 22 4157 8800 Japan 81 045 453 9175 North America 1 978 232 6000 Toll F...

Reviews: