Refrigeration Maintenance (Rev. 12/03)
63
HOT GAS SOLENOID (OPTIONAL)
The hot gas solenoid (or hot gas bypass valve) is used in
conjunction with the electronic throttling valve to reduce
the capacity of the unit during modulation. This normally
closed solenoid valve is located in the refrigeration line that
connects the discharge line to the hot gas line. The hot gas
solenoid is energized (opened) at full modulation. The hot
gas solenoid is de-energized (closed) when modulation is
discontinued.
Refer to THERMOGUARD
µ
P-VI Microprocessor Con-
troller Diagnosis Manual TK 50566 for information about
testing the hot gas solenoid. See the Refrigeration Service
Operation chapter of this manual for removal and installa-
tion procedures.