Operating Instructions (Rev. 12/03)
24
Thermo King Logo Key Allows selection of Pretrip
Test, Print and Start of Trip and displays software
revision and clock/calendar settings.
Clear Key This key is pressed to clear alarm codes
when they are shown on the display.
Code Key Pressing this key displays any alarm codes
that may be present. [00] means no codes are present.
Enter Key Pressing this key will execute a prompt or
load a new setpoint or other setting.
Up and Down Arrow Keys Pressing these keys will
change a displayed prompt or increase/decrease the
setpoint or other setting.
Select Key Pressing this key displays temperature
sensor reading and Sleep Mode Wakeup Time (if pro-
grammed). See the following list.
[DIS.A]
Discharge Air Temp
[TPDF]
Temp Differential
[COIL]
Coil Temp
[AMB.T]
Ambient Temp
[SPR.1]
Spare Sensor 1 Temp
[SPR.2]
Spare Sensor 2 Temp
[DAS.1]
Optional DAS Temp Sensor 1
[DAS.2]
Optional DAS Temp Sensor 2
[DAS.3]
Optional DAS Temp Sensor 3
[DAS.4]
Optional DAS Temp Sensor 4
[DAS.5]
Optional DAS Temp Sensor 5
[DAS.6]
Optional DAS Temp Sensor 6
Computer Port (Optional)
A serial cable from a computer is connected to the down-
load port to access the Data Logging functions of the DAS.
Printer Port (Optional)
A serial cable from a printer is connected to the printer port
to obtain a printout of the data logged by the optional DAS
direct connect connectors.
Summary of Contents for SB-190 30
Page 4: ......
Page 8: ......
Page 14: ...4...
Page 26: ...Unit Description Rev 12 03 16 Front View AJA890...
Page 40: ...Operating Instructions Rev 12 03 30...
Page 74: ...64...
Page 92: ...82...
Page 100: ...90...
Page 113: ...103 SB 100 190 Schematic Diagram Page 1 of 2...
Page 114: ...104 SB 100 190 Schematic Diagram Page 2 of 2...
Page 115: ...105 SB 100 190 Wiring Diagram Page 1 of 5...
Page 116: ...106 SB 100 190 Wiring Diagram Page 2 of 5...
Page 117: ...107 SB 100 190 Wiring Diagram Page 3 of 5...