background image

40

TK 57073-2-IM-EN

Operating the Unit

S

ST

TO

OP

P -- O

ON

NL

LY

Y T

TR

RA

AIIN

NE

ED

D A

AN

ND

D Q

QU

UA

AL

LIIF

FIIE

ED

D IIN

ND

DIIV

VIID

DU

UA

AL

LS

S S

SH

HO

OU

UL

LD

D O

OP

PE

ER

RA

AT

TE

E T

TH

HE

E U

UN

NIIT

T.. R

RE

EF

FE

ER

R T

TO

O Y

YO

OU

UR

R U

UN

NIIT

T

O

OP

PE

ER

RA

AT

TO

OR

RS

S M

MA

AN

NU

UA

AL

L F

FO

OR

R S

SP

PE

EC

CIIF

FIIC

C D

DE

ET

TA

AIIL

LS

S..

High Voltage Safety Precautions

D

DA

AN

NG

GE

ER

R

H

Ha

azza

arrd

do

ou

uss V

Vo

olltta

ag

ge

e!!!!

D

Da

an

ng

ge

erro

ou

uss tth

hrre

ee

e p

ph

ha

asse

e A

AC

C e

elle

eccttrriicc p

po

ow

we

err iiss p

prre

esse

en

ntt w

wh

he

en

ne

ev

ve

err tth

he

e u

un

niitt iiss o

op

pe

erra

attiin

ng

g iin

n D

Diie

esse

ell M

Mo

od

de

e a

an

nd

d

w

wh

he

en

ne

ev

ve

err tth

he

e u

un

niitt iiss cco

on

nn

ne

ecctte

ed

d tto

o a

a sso

ou

urrcce

e o

off e

ex

xtte

errn

na

all sstta

an

nd

db

by

y p

po

ow

we

err.. V

Vo

olltta

ag

ge

ess o

off tth

hiiss m

ma

ag

gn

niittu

ud

de

e cca

an

n b

be

e

lle

etth

ha

all.. E

Ex

xe

errcciisse

e e

ex

xttrre

em

me

e cca

au

uttiio

on

n w

wh

he

en

n w

wo

orrkkiin

ng

g o

on

n tth

he

e u

un

niitt.. IIff tth

he

erre

e iiss a

a rriisskk o

off e

en

ne

errg

giizze

ed

d e

elle

eccttrriicca

all cco

on

ntta

acctt,, a

arrcc,,

o

orr fflla

assh

h,, tte

ecch

hn

niicciia

an

nss M

MU

US

ST

T p

pu

utt o

on

n a

allll P

PP

PE

E iin

n a

acccco

orrd

da

an

ncce

e w

wiitth

h O

OS

SH

HA

A,, N

NF

FP

PA

A 7

70

0E

E,, o

orr o

otth

he

err llo

occa

all,, sstta

atte

e,, o

orr

cco

ou

un

nttrry

y--ssp

pe

ecciiffiicc rre

eq

qu

uiirre

em

me

en

nttss ffo

orr a

arrcc fflla

assh

h p

prro

otte

eccttiio

on

n P

PR

RIIO

OR

R tto

o sse

errv

viicciin

ng

g tth

he

e u

un

niitt.. N

NE

EV

VE

ER

R P

PE

ER

RF

FO

OR

RM

M A

AN

NY

Y

S

SW

WIIT

TC

CH

HIIN

NG

G,, D

DIIS

SC

CO

ON

NN

NE

EC

CT

TIIN

NG

G,, O

OR

R V

VO

OL

LT

TA

AG

GE

E T

TE

ES

ST

TIIN

NG

G W

WIIT

TH

HO

OU

UT

T P

PR

RO

OP

PE

ER

R E

EL

LE

EC

CT

TR

RIIC

CA

AL

L P

PP

PE

E A

AN

ND

D A

AR

RC

C

F

FL

LA

AS

SH

HIIN

NG

G C

CL

LO

OT

TH

HIIN

NG

G.. E

EL

LE

EC

CT

TR

RIIC

CA

AL

L M

ME

ET

TE

ER

RS

S A

AN

ND

D E

EQ

QU

UIIP

PM

ME

EN

NT

T M

MU

US

ST

T B

BE

E P

PR

RO

OP

PE

ER

RL

LY

Y R

RA

AT

TE

ED

D F

FO

OR

R IIN

NT

TE

EN

ND

DE

ED

D

V

VO

OL

LT

TA

AG

GE

E..

High Voltage Components

Various components on the Precedent S-750i unit operate using 460V/60Hz or 537V/70Hz high voltage depending on
unit speed or if Shorepower is connected. These high voltage components are identified by warning nameplates.

RCS1931

537 VAC/70Hz
Can cause serious
shock. Turn unit
off and disconnect
power cord before
removing cover.

WARNING

All high voltage wiring is identified by ORANGE conduit. Be aware of the locations of these components. Only certified,
trained technicians can service them. Refer to the following page for locations of high voltage components.

Unit Fan Operation Safety Precautions

D

DA

AN

NG

GE

ER

R

R

Riisskk o

off IIn

njju

urry

y!!

T

Th

he

e u

un

niitt’’ss C

Co

on

nd

de

en

nsse

err ffa

an

nss a

an

nd

d E

Ev

va

ap

po

orra

atto

orr ffa

an

nss m

ma

ay

y sstta

arrtt a

au

utto

om

ma

attiicca

alllly

y a

an

ny

yttiim

me

e tth

he

e u

un

niitt ssw

wiittcch

h iiss O

ON

N a

an

nd

d cca

an

n

cca

au

usse

e sse

erriio

ou

uss iin

njju

urry

y.. S

Sw

wiittcch

h u

un

niitt tto

o O

OF

FF

F b

be

effo

orre

e sse

errv

viicciin

ng

g..

Condenser and Evaporator Fans

Be aware of the warning nameplates near the condenser fans and evaporator fans.

RCS1931

537 VAC/70Hz
Can cause serious
shock. Turn unit
off and disconnect
power cord before
removing cover.

WARNING

Summary of Contents for Precedent S-750i

Page 1: ...Rev A April 2022 T TK K 5 57 70 07 73 3 2 2 I IM M E EN N Trailer Edition Precedent S 750i Single Temperature Systems Installation Manual...

Page 2: ...u uf fa ac ct tu ur re er r s sh ha al ll l h ha av ve e n no o l li ia ab bi il li it ty y t to o a an ny y p pe er rs so on n o or r e en nt ti it ty y f fo or r a an ny y p pe er rs so on na al l i...

Page 3: ...io on n C Co om mp po on ne en nt ts s 2 23 3 U Un np pa ac ck ki in ng g U Un ni it t 2 24 4 I In ns st ta al ll li in ng g U Un ni it t 2 25 5 Unit Installation 25 Access to Mounting Bolts 25 I In n...

Page 4: ...39 O Op pe er ra at ti in ng g t th he e U Un ni it t 4 40 0 High Voltage Safety Precautions 40 High Voltage Components 40 Unit Fan Operation Safety Precautions 40 Condenser and Evaporator Fans 40 P...

Page 5: ...es ss su ur re e w wh hi ic ch h m mi ig gh ht t c ca au us se e a an n e ex xp pl lo os si io on n r re es su ul lt ti in ng g i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y...

Page 6: ...ev ve er r d dr ri il ll l h ho ol le es s i in nt to o t th he e u un ni it t u un nl le es ss s i in ns st tr ru uc ct te ed d b by y T Th he er rm mo o K Ki in ng g H Ho ol le es s d dr ri il ll l...

Page 7: ...gl lo ov ve es s a an nd d o ot th he er r c cl lo ot th hi in ng g a an nd d e ey ye e w we ea ar r w wh he en n h ha an nd dl li in ng g r re ef fr ri ig ge er ra an nt t t to o h he el lp p p pr r...

Page 8: ...ntact local poison control center or physician E EN NG GI IN NE E C CO OO OL LA AN NT T E Ey ye es s Immediately flush with large amounts of water for at least 15 minutes Get prompt medical attention...

Page 9: ...l l t ta an nk k t to o r re em ma ai in n i in n c co om mp pl li ia an nc ce e w wi it th h F Fe ed de er ra al l M Mo ot to or r C Ca ar rr ri ie er r S Sa af fe et ty y A Ad dm mi in ni is st tr r...

Page 10: ...e en nt t w wi il ll l r re es su ul lt t V VE ER RI IF FY Y T TH HI IS S D DI IM ME EN NS SI IO ON N B BE EF FO OR RE E I IN NS ST TA AL LL LI IN NG G U UN NI IT T N NO OT TI IC CE E E Eq qu ui ip pm...

Page 11: ...he e r re ef fr ri ig ge er ra at ti io on n u un ni it t I Im mp po or rt ta an nt t Location of unit mounting bolts and evaporator opening in front wall is critical VERIFY ALL DIMENSIONS BEFORE INS...

Page 12: ...allow the mounting nuts be torqued to 82 N m 60 ft lbs from outside the trailer S Si ix x unit mounting bolts must extend a m mi in ni im mu um m 57 20 mm 2 25 in and a m ma ax xi im mu um m of 69 85...

Page 13: ...Minimum 57 20 mm 2 25 in Maximum 69 85 mm 2 75 in Minimum 57 20 mm 2 25 in Maximum 63 5 mm 2 50 in A A A A A A A B B C C Minimum 44 45 mm 1 75 in Maximum 63 5 mm 2 50 in T Tr ra ai il le er r R Re eq...

Page 14: ...wn includes the top fairing Some applications such as Domestic Refrigerated Containers DRC and Trailer On Flat Car TOFC with an intermodal guard will not have a top fairing The unit height for these a...

Page 15: ...TK 57073 2 IM EN 15 U Un ni it t D Di im me en ns si io on ns s...

Page 16: ...R669 1 mm 26 34 in R566 2 mm 22 29 in R544 0 mm 21 42 in TOP VIEW LOWER DOOR PANEL RADII R868 4 mm 34 19 in R868 4 mm 34 19 in TOP VIEW UPPER GRILLE RADII NOTE For rail options DRC TOFC door opening r...

Page 17: ...BLE INSTALLATION DEPTH Min 15 4 mm 60 in Max 161 8 mm 6 40 in TYPICAL TRAILER FRONT WALL THICKNESS Min 76 2 mm 3 0 in Max 107 95 mm 4 25 in REFERENCE ONLY Contact Minneapolis Thermo King Service Depar...

Page 18: ...18 TK 57073 2 IM EN Unit Weight Approximate Weight S 750i 998 kg 2200 lbs...

Page 19: ...minimum of 95 amp hr N No ot te e See the following table for Thermo King approved batteries BATTERY APPLICATION TABLE 925 CCA Wet Cell Thermo King ReliaMax 925N P N 203 733 Threaded Stud P N 203 732...

Page 20: ...51 14 4 G Gr ra ad de e B B S St te ee el l P Pl la at te e U UN NS S K K1 11 16 63 30 0 W WA AR RN NI IN NG G R Ri is sk k o of f I In nj ju ur ry y T Th he e l li if ft ti in ng g b ba ar r a an nd...

Page 21: ...be done to both sides of the bar IMPORTANT Welded Lifting Bar Assembly 3 2 1 1 Forged Clevis Pins 2 Forged Chain Links 3 Forged Eyebolts N No ot te e These instructions are provided for fabricating th...

Page 22: ...ape Measure 5 Mechanics Tools 6 Lifting Bar 7 Work Platform Recommended 8 Torque Wrench 9 Forged Eyebolts 5 8 11 N No ot te e Equipment such as scales gauges refrigerant leak detectors and torque wren...

Page 23: ...TK 57073 2 IM EN 23 Installation Components Battery Mounting Kit Solar Panel Mounting Kit Skin Mounting Kit Fuel Pump Kit Drain Tube Kit Unit Mounting Kit Shorepower Kit 6 5 4 3 2 1 7 RCS1930...

Page 24: ...r rr ra an nt ty y o or r c ca au us se e p pe er rs so on na al l i in nj ju ur ry y o or r d de ea at th h N No ot te e A lifting bar can be made from the drawings shown Lifting Bar Dimensions p 20...

Page 25: ...ui ip pm me en nt t D Da am ma ag ge e a an nd d R Ri is sk k o of f I In nj ju ur ry y U Un ni it t m mo ou un nt ti in ng g n nu ut ts s s sh ho ou ul ld d b be e i in ns st ta al ll le ed d u us si...

Page 26: ...26 TK 57073 2 IM EN RCS1922 b c f e d II h a g 1 2 I I In ns st ta al ll li in ng g U Un ni it t...

Page 27: ...Im mp po or rt ta an nt t Upper clamp location varies by individual application while lower clamps should be installed 127 mm 5 00 in up from the bottom of the drain valves and not be so tight as to r...

Page 28: ...conduit provided in the installation kit are to be used to secure the fuel lines to the rear of the frame 1 From the r re eg gu ul la at to or r s st tr ra ai in ne er r S SU UP PP PL LY Y fitting in...

Page 29: ...1 S 750i Fuel Line Connections Without Fuel Heater Shown III 25 4 mm 1 00 in 3 8 RETURN 3 8 SUPPLY 45 x 2 II I RCS1828 1 2 3 1 Fuel Supply 2 Fuel Return 3 Plastic Tube I In ns st ta al ll li in ng g F...

Page 30: ...nduit provided in the installation kit are to be used to secure the fuel lines to the rear of the frame 1 From the fuel heater I IN NL LE ET T fitting install and route 3 8 fuel supply line through th...

Page 31: ...2 S 750i Fuel Line Connections With Fuel Heater Shown III 25 4 mm 1 00 in 3 8 RETURN 3 8 SUPPLY 45 x 2 II I RCS1829 1 2 3 1 Fuel Supply 2 Fuel Return 3 Plastic Tube I In ns st ta al ll li in ng g F F...

Page 32: ...ration on following page 1 Attach interconnect harness 3 pin connector to mating capped off connector F FU UE EL L 0 01 1 F FU UE EL LN N 0 01 1 a an nd d F FU UE EL LP P 0 01 1 located near unit cont...

Page 33: ...r rl ly y i in ns st ta al ll le ed d t to o p pr re ev ve en nt t s se er ri io ou us s i in nj ju ur ry y o or r d de ea at th h T Th he e u un ni it t g gr ro ou un nd d w wi ir re e s su up pp pl...

Page 34: ...3 Allow enough wire to provide a drip loop and cut LED extension harness to proper length 4 P PO OW WE ER R W WI IR RE E Install the fuse holder to the power wire L LE ED DP P 0 07 7 with the butt sp...

Page 35: ...or r r ro ot ta at ti in ng g c co om mp po on ne en nt ts s N No ot te e Thermo King units are designed for one 12 volt group 31 battery The battery must be suitable for deep cycling heavy duty and r...

Page 36: ...36 TK 57073 2 IM EN Roadside Door Roadside Panel RCS1925 1 2 7 5 4 3 1 6 I In ns st ta al ll li in ng g B Ba at tt te er ry y...

Page 37: ...l A 3 Place top covers onto unit a Lift fairing up just enough so the top cover mounting holes are positioned under the fairing mounting tab b Loosely reinstall the M6 screws back down through fairing...

Page 38: ...RCS1926 1 4 1 2 4 tail e B D 5 Fairing tail e A D Top Cover 2 I In ns st ta al ll li in ng g T To op p C Co ov ve er rs s a an nd d B Bo ot tt to om m P Pa an n T Tr ra ai il le er r A Ap pp pl li ic...

Page 39: ...ry harness connector on top of unit behind coolant tank a Remove and discard the cap from the connector b Attach connector to solar panel controller and secure harness to bracket with three supplied b...

Page 40: ...RI IO OR R t to o s se er rv vi ic ci in ng g t th he e u un ni it t N NE EV VE ER R P PE ER RF FO OR RM M A AN NY Y S SW WI IT TC CH HI IN NG G D DI IS SC CO ON NN NE EC CT TI IN NG G O OR R V VO OL...

Page 41: ...nt Locations Front 1 2 3 5 6 7 4 RCS1932 1 Condenser Motors 5 StandBy Power Receptacle under unit 2 Evaporator Motor 6 Electric Generator 3 High Voltage Box 7 Scroll Compressor 4 High Voltage Contacto...

Page 42: ...gine can be started for the first time 1 Enter the M MA AI IN N M ME EN NU U 2 Navigate to F FU UE EL L P PR RI IM ME E and select it 3 Press the S ST TA AR RT T button to begin fuel priming N No ot t...

Page 43: ...Access 1 From the Standard Display press the ACCEPT ENTER center key 2 Press and hold the top right and left soft keys at the same time for five seconds Main Menu will appear 3 In Main Menu navigate t...

Page 44: ...ter Guarded Access If the correct access code is not entered access to Guarded Access will be denied If no access code has been set the controller will enter Guarded Access directly 5 In Guarded Acces...

Page 45: ...ds at normal engine running temperature High Speed and Low Speed per maintenance manual Check 70 F 21 C box temperature and 70 F 21 C ambient Set for continuous run with thermostat set point at 32 F 0...

Page 46: ...lant refrigerant and exhaust leaks Check engine oil and coolant level Check entire unit for loosened hardware and fittings Check and adjust all skin door and panels for correct alignment and operation...

Page 47: ...TK 57073 2 IM EN 47 N No ot te es s...