Servicing The Unit
153
•
MAGNUM 20 Model: 0 to 160 m
3
/hr. (0
and 96 ft
3
/min.).
•
MAGNUM SL and MAGNUM Models: 0
to 125 m
3
/hr. (0 and 75 ft
3
/min.).
3. Tighten the wing nut.
Handle Adjustment: High Ventilation
Rates
To make a handle adjustment, perform the
following steps:
1. Loosen wing nut on handle assembly until
handle bracket will rotate over handle.
2. Align handle bracket and wing nut over hole
in handle assembly and push through handle.
3. Pull handle down to lower ventilation door.
Insert edge of ventilation door in a notch on
handle. Spring loaded handle holds ventilation
door in position. Air exchange rate is shown
on the handle scale:
•
MAGNUM SL and MAGNUM Models:
150, 225 and 280 m
3
/hr. (90, 135 and
165 ft
3
/min.).
1.
Disk Scale: Low Ventilation Rates
2.
Disk Assembly with Rate Indicator
3.
CO
2
Port
4.
Ventilation Door
5.
Handle Assembly with Scale: High
Ventilation Rates (MAGNUM SL &
MAGNUM Models Only)
6.
Handle Bracket
7.
Wing Nut
Figure 102: Air Exchange System
2
3
5
6
7
4
1
AXA0195
Summary of Contents for 098916
Page 5: ......
Page 11: ...Table of Contents 10...
Page 19: ...Service Guide 18...
Page 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Page 41: ...Unit Description Features Options 40...
Page 105: ...Operating Instructions 104...
Page 155: ...Servicing The Unit 154...
Page 187: ...Index 186...
Page 189: ...Wiring and Schematic Diagrams Index 188...
Page 190: ...189 Wiring Schematic...
Page 191: ...190 Wiring Diagram Page 1 of 2...
Page 192: ...191 Wiring Diagram Page 2 of 2...