Refrigeration Service Operations
93
5. Pressurize the low side and test for leaks. If no
leaks are found, evacuate the low side.
6. Replace the access panels.
7. Open the refrigeration valves and place the
unit in operation.
8. Test the unit to see that the expansion valve is
properly installed.
Figure 62: Location of Expansion Valve Bulb
Heat Exchanger
Removal
1. Pump down the low side and equalize the
pressure to slightly positive.
2. Remove the evaporator access panels.
3. Remove the hardware that holds the heat
exchanger on the bulkhead.
4. Unsolder the liquid outlet line.
5. Unsolder the suction inlet line.
6. Unsolder the remaining outlet suction line and
inlet liquid line connections from the
condenser side of the bulkhead. Remove any
putty from around the lines before unsoldering
the connections.
7. Slide the heat exchanger assembly out of the
evaporator housing.
Installation
1. Clean the tubes for soldering.
2. Place the heat exchanger assembly in the
evaporator housing and install the mounting
hardware loosely.
3. Solder the liquid inlet and the suction outlet
line connections on the condenser side of the
bulkhead. Seal the openings through the
bulkhead with putty when the refrigerant lines
have cooled off.
4. Solder the suction inlet line connection.
5. Solder the liquid outlet line connection.
6. Pressurize the low side and test for leaks. If no
leaks are found, evacuate the low side.
7. Tighten the heat exchanger mounting
hardware securely.
8. Replace the evaporator access panels.
9. Open the refrigeration valves and place the
unit in operation.
Evaporator Coil
NOTE: This procedure applies to the
Zone 1/Host unit evaporator coil.
Removal
1. Pump down the low side and equalize the
pressure to slightly positive.
2. Remove the evaporator access panels and
damper assembly.
3. Disconnect and remove the sensors.
4. Remove the feeler bulb from the suction line
clamp. Note the position of the feeler bulb on
the suction line.
5. Unsolder the distributor from the expansion
valve.
6. Unsolder the hot gas line and the suction line
from the evaporator coil.
7. Remove the mounting bolts, lift and slide the
coil from the housing.
Installation
1. Place the evaporator coil in the evaporator
housing and install the mounting bolts.
1.
End View
2.
Side View
AEA713
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...