Specifications
15
Electrical Control System
Voltage
12.5 Vdc
Battery
One, group C31, 12 volt battery
Circuit Breaker CB1—Zone 2 Fan Motors
30 amp, auto reset
Circuit Breaker CB2—Zone 3 Fan Motors
30 amp, auto reset
Fuse Link Rating
110 amps @ 72 F (22 C)
Fuse F2—Electric Contactors
5 amp
Fuse F3—Zone 1 Damper
15 amp
Fuse F4—High Speed (Throttle) Solenoid
15 amp
Fuse F6—Zone 1 (Host) Solenoids
15 amp
Fuse F12—Zone 3 Fan Motors
25 amp
Fuse F13—Zone 3 Solenoids
15 amp
Fuse F15—Zone 2 Fan Motors
25 amp
Fuse F16—Zone 2 Solenoids
15 amp
Fuse F20—Control Circuit Power
40 amp
Fuse F22—Host Unit Controls
25 amp
Fuse F23—Starter Circuit
40 amp
Other Fuses
2 or 5 amp
Battery Charging:
Model 30
12 volt, 120 amp, brush type alternator
Model 50
12 volt, 105 amp, brush type alternator
Voltage Regulator Setting
13.8 to 14.3 volts @ 77 F (25 C)
NOTE: Fuse F7 (Bypass resistor for Prestolite Alternator) must be removed for the Bosch Alternator.
The Bosch alternator has the word “BOSCH” on the end opposite the pulley (see Figure 17 on page 43).
Electrical Components
NOTE: Disconnect components from unit circuit to check resistance.
Current Draw (Amps)
at 12.5 Vdc
Resistance—Cold
(Ohms)
Fuel Solenoid:
Pull-in Coil
35 to 45
0.2 to 0.3
Hold-in Coil
0.5
24 to 29
Damper Solenoid
5.7
2.2
High Speed (Throttle) Solenoid
2.9
4.3
Condenser Inlet Solenoid
1.3
9.6
Liquid Line Solenoid in Host Unit
1.5
8.3
Liquid Line Solenoids in Remote Units
1.3
9.6
Hot Gas Solenoids
1.5
8.3
Suction Line Solenoids
1.3
9.6
Receiver Tank Pressure Solenoid
0.7
17.0
Purge Valve
0.7
17.0
Air Heater
70.0-89.0
0.14
Starter Motor—Gear Reduction Type
250-375*
*On-the-engine cranking check. Bench test is approximately 100 amps on the direct drive starter and approximately 80 amps
on the gear reduction starter.
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...