Defrost Damper
Check the damper during scheduled maintenance
inspections for shaft wear, end play, and the
ability to stop the air flow.
Position the damper so that air flow is stopped on
the top and bottom edges with the solenoid
plunger bottomed out.
To adjust the damper:
1. Remove the damper assembly from the
evaporator.
2. Disconnect the damper link from the eye bolt.
3. Check Distance A, the distance from the
shoulder on the solenoid to the center of the
hole in the eye bolt. Distance A should be
2.75 in. (69.85 mm) with the solenoid
de-energized.
4. If necessary, adjust Distance A to the proper
dimension by loosening the locknut on the end
of the solenoid plunger and turning the eye
bolt. Tighten the locknut when Distance A is
correct.
5. Connect the damper link to the eye bolt.
6. Energize the solenoid (apply 12 volts dc) and
check the damper blade to make sure that both
edges contact the damper housing. If
necessary, adjust this by loosening the
solenoid mounting bolts and moving the
solenoid. Tighten the solenoid mounting bolts
when both edges of the damper blade contact
the damper housing.
7. Adjust the damper blade stops so they contact
the edges of the damper blade. This keeps the
damper from sticking closed.
1.
Stop
6.
Eye Bolt
2.
Mounting Bolts
7.
Round Stop
3.
Closed Position
8.
Distance A 2.75 in. (69.85 mm)
4.
Open Position
9.
Solenoid
5.
Damper Link
Figure 72: Defrost Damper Adjustment
AEA719
1
2
9
8
1
7
4
3
5
6
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...