105
Structural Maintenance
Unit and Engine Mounting Bolts
Check and tighten all unit and engine mounting
bolts during scheduled maintenance inspections.
Torque the unit mounting bolts to 60 ft-lb
(81 N•m). Torque the engine mounting bolts to
150 ft-lb (203 N•m).
Unit Inspection
Inspect the unit during pretrip inspection and
scheduled maintenance inspections for loose or
broken wires or hardware, compressor oil leaks,
or other physical damage which might affect unit
performance and require repair or replacement of
parts.
Condenser, Evaporator, and
Radiator Coils
Clean the coils during scheduled maintenance
inspections. Remove any debris (e.g., leaves or
plastic wrap) that reduces the air flow. Clean dirty
coils with compressed air or a pressure washer. Be
careful not to bend the fins when cleaning a coil.
If possible, blow the air or water through the coil
in the direction opposite the normal airflow.
Repair bent fins and any other noticeable damage.
Defrost Drains
Clean the defrost drains during scheduled
maintenance inspections to be sure the lines
remain open.
Unit Installation
All nuts that hold the unit to the trailer are
accessible using an impact wrench with a 10 in.
extension, ball-type swivel and a deep-well
socket.
NOTE: The nuts for mounting the unit should
be elastic stop nuts (Nylock type).
1.
Check Bolts for Tightness
Figure 71: Unit and Engine Mounting Bolts
1
ARA104
ARA106
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...