7
Installation:
1. The heater should be installed by a qualified plumber.
We recommend the use of a knee pad when installing this
product. Cut the opening in the plinth to the size shown in
the table. Use method A or B.
Note:
When Method B is
used please make sure that the heater base sits on the
solid support.
Model
Width A Height B*
KPH 1300/1500/1800/2100
456mm
97mm
KPH-2400
540mm
97mm
* The overall height of the grille is 100mm. Use care when
cutting the opening.
2. Fit isolating valves (not supplied) to the system
flow and return pipes. Failure to fit isolating valves
may mean that the product is not serviceable in
the event of failure. Remove and discard the two
rubber protection bungs in the copper pipes and
connect the flexible hoses between heating
system pipework and heater.
Open the isolating valve on the flow pipe (keep
the isolating valve on the return pipe closed) and
check for leaks.
N.B. either pipe may be used on flow or return.
3. Vent air through bleed screw if necessary
with flat blade screw driver. Once the air is
removed you can now open the isolating valve
on the return pipe to get the water flowing.
Flate heat
screw driver
Bleed Valve
I
O
II
Flow
Return
Method A
A
A
B
B
Method B