1. The heater should be installed by a qualified plumber. 
We recommend the use of a knee pad when installing this 
product. Cut the opening in the plinth to the size shown in 
the table. Use method A or B. 

Note:

 

When Method B is 

used please make sure that the heater base sits on the 
solid support. 

Model 

Width A  Height B* 

KPH 1300/1500/1800/2100 

456mm 

97mm 

KPH-2400 

540mm 

97mm 

* The overall height of the grille is 100mm. Use care when 
cutting the opening. 

 

 

 

 

2. Fit isolating valves (not supplied) to the system 
flow and return pipes. Failure to fit isolating valves 
may mean that the product is not serviceable in 
the event of failure. Remove and discard the two 
rubber protection bungs in the copper pipes and 
connect the flexible hoses between heating 
system pipework and heater.  

Open the isolating valve on the flow pipe (keep 
the isolating valve on the return pipe closed) and 
check for leaks.  

N.B. either pipe may be used on flow or return. 

 

3. Vent air through bleed screw if necessary 
with flat blade screw driver. Once the air is 
removed you can now open the isolating valve 
on the return pipe to get the water flowing. 

 Flate heat 
screw driver

Bleed Valve

I

O

II

 

Flow 

Return 

Method A 

A

A

B

B

 

Method B 

 

Summary of Contents for & KPH-2400SW

Page 1: ...KPH 1500 C KPH 1800 C KPH 2100 C KPH 2400C KPH 1500 W KPH 1800 W KPH 2100 W KPH 2400W KPH 1500 SW KPH 1800 SW KPH 2100 SW KPH 2400SW KPH 1500 VC KPH 1800VC KPH 2100 VC Classic Models Wireless Models A...

Page 2: ...gh them thoroughly before use and retain them for future reference Technical information 3 Safety warnings 4 Installer important notes 5 Pre installation 6 Installation 7 8 Commissioning 9 Fault Findi...

Page 3: ...malfunction and contact the manufacturer before you put it into operation again Model Speed Output 75 C watts Output 70 C watts Output 65 C watts Output 60 C watts Output 55 C watts Output 50 C watts...

Page 4: ...g as it could be damage the skin SAFETY INSTRUCTIONS The item should be only used as intended The product is for indoor and domestic use only Check item carefully before use Do not turn on the heater...

Page 5: ...sition 1 or 2 Check with your boiler running that the two pipes on the side of the heater are too hot to hold the unit has an internal temperature sensor that need water to be above 40 degrees before...

Page 6: ...heating systems Flow and return and pipes should be connected as per drawing mentioned in page 2 This unit should not be installed in one pipe system To allow enough airflow a minimum clearance of 20...

Page 7: ...the system flow and return pipes Failure to fit isolating valves may mean that the product is not serviceable in the event of failure Remove and discard the two rubber protection bungs in the copper...

Page 8: ...an in compliance with local regulations I O II Fused Spur 5 Position heater making sure the flexible hoses is not kinked and the electrical cable is not snagged IMPORTANT Smart Wi Fi and Voice control...

Page 9: ...n the central heating system 4 Set any room thermostat s to maximum 5 Check pipework connections for leaks 6 Set the switch to l the fan should run and heat will flow within a few minutes if water tem...

Page 10: ...se make sure that this unit is earthed and reduce the fuse size to 3A use the supplied fuse Recycling Products with this symbol crossed out wheelie bin cannot be disposed as household waste Old electr...

Page 11: ...11...

Page 12: ...the central heating system Outside the UK Misuse or abuse lack of maintenance failure of consumable items such as batteries accidental damage Loss of use of the goods Thermix British built products ar...