5.4
Adjusting the Heat Curve
CURVE
MIN
MAX
CURVE +5
CURVE -5
CURVE 0
HEAT STOP
40 C
20 C
55 C
0 C
0 C
0 C
17 C
HEAT CURVE
1. Open the HEAT CURVE menu in the INFORMATION menu.
2. Select the parameter required using the
or
button.
3. Open the parameter by pressing the right button once
.
4. Increase or reduce the value with the
or
but-
ton.
5. Press the left button three times
to exit.
Note! If your house has under floor heating and heat sensitive floors, the supply line temperature must not
exceed certain temperatures. Otherwise the floor might get damaged.
Parameter
Description
CURVE
If the CURVE value is increased, the heat curve will become steeper; if the value is reduced, it
will become flatter and less heat will be supplied when it gets colder. Raise to increase indoor
temperatures, reduce to lower indoor temperatures. (The factory setting is 40 for radiator sys-
tems and 30 for floor heating.)
MIN
Lowest setpoint for supply temperature. (Normally 20°C.)
MAX
Highest setpoint for supply temperature. (Caution - high supply line temperature may cause
damage to e.g. floors with floor heating.)
CURVE 5
Used to fine tune the heat curve at an outdoor temperature of +5°C.
CURVE 0
Used to fine tune the heat curve at an outdoor temperature of 0°C.
CURVE -5
Used to fine tune the heat curve at an outdoor temperature of -5°C.
HEAT STOP This function stops all production of heat when the outdoor temperature is equal to, or higher
than, the heat stop value currently set.
REDUCTION This function is not used in standard applications, but when used, this setting is used to set
desired reduction of ROOM value when the external control is active. (Also hot water produc-
tion may be affected when the external signal is active.)
40
C
-
C
1
2
3
5
4
1
Supply temperature (°C)
2
Maximum setpoint value
3
Outdoor temperature (°C)
4
0°C
5
Set value (standard 40°C)
User Guide
Thermia Legend
BWLE01UG0102
Thermia AB
14
ROOM
FACTOR
Used to adjust the influence of the ROOM value. Default 3. (2 can be used for e.g. floor
heating). Also used for room sensor influence (if installed).