12.
POSSIBLE FAULTS AND REMEDIES.
Malfunction
Possible cause
How to fix
Hot water pressure
from EWH decreased.
Cold water pressure
keeps at the level.
Clogged
inlet
safety valve
Remove the valve and clean
it in water
Heating
time
increased
THE is covered
with a layer of sludge
Remove the flange and
clean the THE
Supply voltage decreased Contact power main operation ser-
vice
Frequent tripping
of thermal switch
The set temperature
is close to the limit
Set lower value of water
heating temperature
Thermostat tube is cov-
ered with sludge
Take out the EWH the re-
movable flange and gently clean
the tube from scale
EWH operates but is not
heating water
Valve (Fig. 1, p.8)
is not closed or out of or-
der
Close or replace the valve (Fig. 1,
p. 8)
Powered EWH does not
heat water. No backlights
of indicator lamps.
1) no voltage in electric
network;
2) damaged power cord.
3) Thermal switch actu-
ated and not switched
on
1) Check voltage at the electrical
outlet;
2) Contact a qualified service cen-
ter.
3) Disconnect from the power
supply, remove EWH protective
cover, press the button on ther-
mal switch until you hear a click
(fig. 2) install the cover and turn
on the power
These faults are not defects of EWH and shall be fixed by the consumer or by a
specialized organization at his own expense.
In case of failure to fix problems using the above recommendations or in case of
others problems revealing you should contact the authorized service center listed in the
operation manual.
ы
EN
Summary of Contents for ID 100 V (smart)
Page 2: ......
Page 14: ...12 THERMEX THERMEX THERMEX THERMEX ID smart 1 0 05 0 8 2 1 GP 1 1 1 1 RU...
Page 16: ...14 1 5 1 14 1 6 1 15 5 0 8 3 40 RU...
Page 18: ...16 8 1 5 1 3 3 5 4 1 RU...
Page 19: ...17 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 11 1 12 RU...
Page 20: ...18 5 1 4 1 0 8 9 2000 10 2 RU...
Page 22: ...20 RU...
Page 23: ...21 12 1 8 1 8 1 2 3 1 2 3 2 RU...
Page 24: ...22 13 10 20 14 9 15 2 5 2 RU...
Page 126: ...124...