80 PLUS Verification and Testing Report

TYPICAL EFFICIENCY (50% Load):

AVERAGE EFFICIENCY :

80 PLUS COMPLIANT:

YES

Value

Units

100-240 Volts

8/4

Amps

47-63

Hz

650

Watts

Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.

Input AC Current Waveform (ITHD = 8.02%, 50% Load)

I

RMS

PF

A

12V1

12V2

12V3

12V4

-12V

3.3V

5V*

5VSB

1.43

1.00

10.2%

20%

Light

162

12/2.2

12/2.2

12.1/2.2

12/2.2

12.1/0.1

3.3/2.7

5/2.6

5.1/0.4

130

80.46%

3.36

0.99

8.0%

50%

Typical 

384

12/5.5

12/5.5

12/5.5

11.9/5.5

12.1/0.2

3.3/6.9

5/6.4

5/0.9

324

84.28%

6.91

1.00

7.1%

100%

Full

792

11.9/10.9

11.9/10.9

12/10.9

11.9/10.9 12.3/0.5

3.2/13.7

5/12.8

5/1.8

643

81.20%

Tested by Electric Power Research Institute, Knoxville, TN.

84.28%
81.98%

Thermaltake
W0128RU
64446649
2006

Manufacturer

Test Date 

Input Frequency

157.2

Type

Ecos ID #

Model Number
Serial Number
Year

ATX12V

Input 
Watts

Fraction 
of Load

DC Terminal Voltage (V)/ DC Load Current (A)

Output 

Watts

1/11/2007

Efficiency 

%

Rated Output Power

Load 

(%)

Rated Specifications

Input Voltage
Input Current

I

THD

 (%)

Input and Output Power

Input Watts

Output Watts

0

100

200

300

400

500

600

700

800

900

20%

50%

100%

Loading (% of Rated Output Power)

P

o

w

e

(W

a

tt

s

)

Efficiency of the Power Supply

30%

40%

50%

60%

70%

80%

90%

0%

25%

50%

75%

100%

125%

Loading (% of Rated Output Power)

E

ff

ic

ie

n

c

y

 (

%

)

Efficiency %

These tests were conducted as a part of the 80 PLUS program.  80 PLUS is 
a computer buy-down program to promote high-efficiency power supplies 
(greater than 80% efficiency in the active mode) in desktop computers and 
desktop-derived servers.

Input Current and Voltage Waveforms

-200

-150

-100

-50

0

50

100

150

200

0

0.003

0.006

0.009

0.012

0.015

Time (s)

V

o

lta

g

e

 (

V

)

-20

-15

-10

-5

0

5

10

15

20

C

u

rr

e

n

(A

)

Voltage 

Current