background image

80 PLUS Verification and Testing Report

TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:

YES

Value

Units

100-240 Volts

10

Amps

47-63

Hz

750

Watts

Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.

Input AC Current Waveform (ITHD = 7.42%, 50% Load)

I

RMS

PF

A

-12V

3.3V

5V*

5VSB

1.65

0.94

15.0%

20%

Light

178

12.1/0.1

3.3/3.2

5.1/2.9

5.1/0.4

152

85.33%

3.83

0.98

7.4%

50%

Typical 

433

12.2/0.3

3.3/7.9

5.1/7.4

5/1.1

377

86.98%

7.80

0.99

4.9%

100%

Full

893

12.4/0.6

3.2/15.8

5/14.7

4.9/2.1

744

83.31%

Tested by Electric Power Research Institute, Knoxville, TN.

86.98%
85.21%

THERMALTAKE
W0117 Toughpower 750 AP
NA
2008

Manufacturer

Test Date 

Input Frequency

928

Type

Ecos ID #

Model Number
Serial Number
Year

ATX12V & EPS12V

Input 
Watts

Fraction 
of Load

DC Terminal Voltage (V)/ DC Load Current (A)

Output 

Watts

12V (cumulative of 12V1, 12V2, etc.)

12.1/10.2

12/25.4

11.9/50.6

7/11/2008

Efficiency 

%

Rated Output Power

Load 

(%)

Rated Specifications

Input Voltage
Input Current

I

THD

 (%)

Input and Output Power

Input Watts

Output Watts

0

100

200

300

400

500

600

700

800

900

1000

20%

50%

100%

Loading (% of Rated Output Power)

P

o

w

e

r (W

atts)

Efficiency of the Power Supply

30%

40%

50%

60%

70%

80%

90%

0%

25%

50%

75%

100%

125%

Loading (% of Rated Output Power)

E

fficien

cy (%

)

Efficiency %

These tests were conducted as a part of the 80 PLUS program.  80 PLUS is 
a computer buy-down program to promote high-efficiency power supplies 
(greater than 80% efficiency in the active mode) in desktop computers and 
desktop-derived servers.

Input Current and Voltage Waveforms

-200

-150

-100

-50

0

50

100

150

200

0

0.003

0.006

0.009

0.012

0.015

Time (s)

V

o

lt

age (V

)

-15

-10

-5

0

5

10

15

C

u

rrent (A

)

Voltage 

Current 

Reviews: