10.1.4 Removing the Electronics Box
Follow the steps shown in the “Removing the Indoor PCB” in the previous section. The
transformer and circuit board power wires do not need to be disconnected to remove the
electronics box, however, they may need to be disconnected to gain access to other
connectors that need to be disconnected.
1.
Remove the screw for the ground wire in the location shown above.
2.
Remove the screw on the bottom of the electronics box. See picture for location.
3.
Lift and pull from the bottom of the electronics box. Make sure that the clip on the
top of the box clears the plastic hook.
After removing the electronics box, the indoor fan motor can be seen behind it. To replace, just reverse the steps above.
Summary of Contents for 12H47YIMI
Page 10: ...10 1080 mm 226 mm 335 mm 30H48ZIMI 49 57 1259 mm 11 1 282 mm 14 25 362 mm 36H46ZIMI...
Page 19: ...19 Model Voltage V Capacity BTU Type 12H47ZOMI 230 12 000 HEAT PUMP...
Page 56: ...56 P W N U...
Page 57: ...57 N V N W...
Page 82: ...82 7 Then lift the PCB assembly off the unit NOTE All wires are still connected...