PRIOR TO INSTALLATION

Step 1: EXHAUST-AIR MODE

D

Exhaust air should neither be directed into a smoke or

exhaust flue that iscurrently used for other purposes, not

into a shaft that is used for ventilating rooms in which 

stoves or fireplaces are also located.

Exhaust air may be discharged in accordance with

official and statutory regulations only (e.g. national

building regulations).

Local authority regulations must be observed when 

discharging air into smoke or exhaust flues that are not

otherwise in use.

D

When the extractor hood is operated in exhaust-air

mode simultaneously with a different burner which

also makes use of the same chimney 

(such as gas, oil

or coal-fired heaters, continuous-flow heaters, hot-water

boilers) care must be taken to

ensure that there is an

adequate supply of fresh air 

which will be needed by

the burner for combustion.
Safe operation is possible provided that the underpressure

in the room where the burner is installed does not exceed

4 Pa (0.04 mbar).
This can be achieved if combustion air can flow through

non-lockable openings, e.g. in doors, windows and via the

air-intake/exhaust-air wall box or by other technical 

measures, such as reciprocal interlocking, etc.

If the air intake is inadequate, there is a risk of 

poisoning from combustion gases which are drawn

back into the room.

An air-intake/exhaust-air wall box by itself is no guarantee

that the limiting value will not be exceeded.
Note: When assessing the overall requirement, the 

combined ventilation system for the entire household must

be taken into consideration. This rule does not apply to

the use of cooking appliances, such as hobs and ovens.

!

The fan must be attached at least 78 

3

/

4

” from the

extractor hood.

!

Attach the inner wall fan inside the building only, but

not in living rooms.

!

When attaching the inner wall fan, ensure that it is

accessible for maintenance and repairs.

!

The plug-and-socket connections of the electric

cables must be located inside the building, according to

local code.

!

Do not reduce the 6” diameter of the pipes connected

to the extractor hood.

PRIOR TO INSTALLATION

Step 2: PREPARING THE WALL

The wall must be flat and perpendicular.

Ensure that the wall is capable of providing a firm hold

for mounting screws and plugs.

Weight in kg: 8,8

We reserve the right to construction changes within the 

context of technical development.

Summary of Contents for VTI610D

Page 1: ...VENTILATION INSTALLATION MANUAL MODELS CVS2 MODEL VTI610D VENTILATION INSTALLATION MANUAL ...

Page 2: ...PAGE 2 ...

Page 3: ...RY TO PER SONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturers guid...

Page 4: ... in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the...

Page 5: ...ting boreholes Insert wall plugs and screw the fan to the wall 4 Connect the pipe from the fan to the extractor hood and feed to the outside 5 Connect the fan to the extractor hood with an extension cable if required Use the added connector Use the wire diagramm for connecting The additional cover on the plug must always be attached and closed for safety reasons Not needed wires must be isolated c...

Page 6: ...PAGE 4 WIRE DIAGRAMM brown green yellow orange blue red white N speed 1 red speed 2 blue speed 3 orange speed 4 brown N white PE green yellow ...

Page 7: ...OU DE PRÉJUDICE PHYSIQUE RESPECTEZ LES CONSIGNES SUIVANTES A Tout travail d installation ou câblage électrique doit être réalisé par une ou des personnes quali fiées conformément à tous les codes et normes applicables y compris ceux relatifs à la construc tion résistante au feu B Une circulation d air efficace est requise afin d as surer la combustion et l évacuation complète des gaz par le tuyau ...

Page 8: ...ouses d admission d évacuation de l air fixées au mur ou grâce à d autres mesures techni ques telles qu un verrouillage réciproque Si l admission d air est mauvaise il existe un risque d intoxication par les gaz dégagés lors de la combus tion qui sont réacheminés dans la pièce Une ventouse d admission ou d évacuation d air fixée au mur ne constitue pas à elle seule une garantie que la valeur limit...

Page 9: ...ilateur dans le mur 4 Connectez la conduite venant du ventilateur à la hotte aspirante et branchez la vers l extérieur 5 Connectez le ventilateur à la hotte aspirante à l aide d un câble de prolongement si nécessaire Utilisez le connecteur supplémentaire Pour effectuer les branche ments se reporter au schéma de câblage Pour des raisons de sécurité le couvercle de prise supplémentaire doit toujours...

Page 10: ...AGE 4 SCHÉMA DE CÂBLAGE marron vert jaune orange bleu rouge blanc N vitesse 1 rouge vitesse 2 bleu vitesse 3 orange vitesse 4 marron N blanc PE vert jaune noir orange blanc bleu marron rouge N vert jaune ...

Page 11: ...en ser realizados por persona s calificada s de conformidad con todos los códigos y normas aplicables incluidos los de construcción con rela ción a incendios B Se requiere aire suficiente para la correcta com bustión y extracción de los gases a través del tubo de humo chimenea del equipo quemador de combustible para prevenir el contratiro Siga las pautas del fabricante del equipo de calefac ción y...

Page 12: ...a través de cajas de entrada salida de aire en la pared o mediante otras medidas técnicas como enclavamiento recíproco etc Si la entrada de aire es insuficiente existe un riesgo de intoxicación con los gases de la combustión que vuel ven a ingresar a la habitación Una caja de entrada salida de aire en la pared por sí sola no garantiza que no se superará el valor límite Nota Al evaluar el requisito...

Page 13: ...atornille el ventilador a la pared 4 Conecte la tubería del ventilador a la campana extracto ra y pásela hacia el exterior 5 Conecte el ventilador a la campana extractora con un cable de extensión si fuera necesario Use el conector adicional Use el diagrama de cableado para realizar la conexión Por motivos de seguridad la tapa adicional sobre el enchufe siempre debe estar colocada y cerrada Los ca...

Page 14: ...A DE CABLEADO marrón verde amarillo naranja azul rojo blanco N velocidad 1 rojo velocidad 2 azul velocidad 3 naranja velocidad 4 marrón N blanco PE verde amarillo negro naranja blanco azul marrón rojo N verde amarillo ...

Page 15: ......

Page 16: ...5551 McFadden Avenue Huntington Beach CA 92649 800 735 4328 www thermador com 9000180879 10013 RevB 10 06 BSH Home Appliances Corporation Litho in U S A ...

Reviews: