background image

Installation Instructions

English | 4 |

Safety

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

INSTALLER: 

Save these instructions for the local electrical

inspector’s use. Please leave these instructions with this

unit for the owner. Show the owner the location of the

circuit breaker or fuse. Mark it for easy reference. 

OWNER:

 Please retain these instructions for future

reference.

WARNING

If the information in this manual is not followed exactly,

ire or shock may result causing property damage or

personal injury.

WARNING

If the information in this manual is not followed 

exactly, ire or shock may result causing proper

-

ty damage, personal injury or death.

 -

DO NOT store or use gasoline or other lammable

 

  vapors and liquids in the vicinity of this or any other 

 apppliance.

 - WHAT TO DO IF YOU SMELL GAS

 

DO NOT try to light any appliance.

 

DO NOT touch any electrical switch.

 

DO NOT use any phone in your building.

 

Immediately call your gas supplier from a  

  neighbor’s phone. Follow the gas supplier’s  

 instructions.

 

• If you cannot reach your gas supplier, call the ire

 

 department.

 - Installation and service must be performed by an 

  authorized servicer, service agency or the gas supplier.

WARNING

Turn off power circuit at service panel and lock out panel

before wiring this appliance. Requirement: 120 VAC, 60

Hz 15 A. Allow the appliance to cool after the power has

been turned off before servicing the appliance.

WARNING

Automatically Operated Device 

To reduce the risk of injury disconnect from power supply 

before servicing.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

 

Use this unit only in the manner intended by the 

  manufacturer. If you have questions, contact the 

  manufacturer at the address or telephone number 

  listed on the back page.

 

Before servicing or cleaning unit, switch power off at 

  service panel and lock the service disconnecting 

  means to prevent power from being switched on 

  accidentally. When the service disconnecting means 

  cannot be locked, securely fasten a prominent 

  warning device, such as a tag, to the service panel.

WARNING

DO NOT

 repair or replace any part of the appliance

unless speciically recommended in the manuals.

Improper installation, service or maintenance can cause

injury or property damage. Refer to this manual for

guidance. All other servicing should be done by an 

authorized servicer.

WARNING

ELECTRICAL SHOCK HAZARD

 

DO NOT remove connections.

 

DO NOT use an extension cord.

 

Failure to follow these instructions can 

  result in death, ire, or electrical shock.

Summary of Contents for Masterpiece HMIB36WS

Page 1: ...Installation INSTRUCTIONS Thermador Masterpiece Island Hood THERMADOR COM...

Page 2: ...HERMADOR COM Installation INSTRUCTIONS Thermador Masterpiece Island Hood Table of Contents English 3 Table de Mati res Fran ais 23 ndice de Cap tulos Espa ol 43 Models Mod les Modelos HMIB36WS HMIB42W...

Page 3: ...ist 22 Before Calling Service 22 Product Data Rating Plate 22 Service Parts Accessories back page Safety Definitions WARNING This indicates that death or serious injuries may occur as a result of non...

Page 4: ...the gas supplier WARNING Turn off power circuit at service panel and lock out panel before wiring this appliance Requirement 120 VAC 60 Hz 15 A Allow the appliance to cool after the power has been tu...

Page 5: ...WARNING State of California Proposition 65 Warnings This product can expose you to chemicals including vinyl chloride which is known to the State of California to cause cancer and birth defects or oth...

Page 6: ...or the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close itting lid cookie sheet o...

Page 7: ...e start of the installa tion Use one hand to maintain the assembly duct cover steady while the other hand removes the protective ilm Tools and Parts Needed Ducting as needed refer to Equivalent Duct L...

Page 8: ...MIB36WS and HMIB42WS This model series is 233 16 588 mm in depth and feature brushed stainless steel canopy with LED lights inches mm 8 200 36 914 42 1067 27 686 183 8 467 23 4 70 DUCTED MIN 30 762 MA...

Page 9: ...ktop range installations Mount the hood so the bottom is at least 30 76 2 cm above the cooking surface NOTICE The hood could incur some damage from heat if a THERMADOR MASTERPIECE series cooktop is op...

Page 10: ...ents and or standards apply to speciic installations DO NOT USE FLEXIBLE DUCT it creates back pressure air turbulence and reduces performance Always use metal ductwork Always install a metal vent cove...

Page 11: ...2 6 5 6 2 2 5 8 3 8 2 2 2 10 10 3 x 10 90 elbow round N A 5 2 long 3 x 10 flex N A 20 3 x 10 45 elbow round N A 15 3 x 10 Flat elbow N A 20 6 1 8 10 8 2 3 x 10 Roof jack and shutter N A 6 5 6 10 NOTE...

Page 12: ...mm round duct system is needed for installation not included NOTE Flexible duct is not recommended Flexible ductwork creates back pressure and air turbulence that greatly reduce performance Vent syst...

Page 13: ...nd support must be provided in all types of installations At the hood location install 2 x 4 cross framing between ceiling joists as shown 2 x 4 are required to support the weight of the hood Arrange...

Page 14: ...l the hole locations for screws and duct in the ceiling 3 Install the upper duct cover brackets on one of the horizontal supports 4 Fix the the upper horizontal support the one with the upper duct cov...

Page 15: ...the blower housing under the structure 2 Attach the blower housing to the lower vertical supports with 2 leveling screws 3 Secure it with 16 installation screws See the image below Mounting the upper...

Page 16: ...the upper side of the blower housing 4 Install the two cable holders into the blower housing 5 Pass the cable connector under the holders and secure them 6 Plug the wire connector assembly supplied w...

Page 17: ...L listed or CSA approved strain relief C Black wires D UL listed wire connectors E White wires F Green or bare and yellow green ground wires A B C D E F Use UL listed wire connectors and connect black...

Page 18: ...allation as shown below view is shown facing wall 135 8 346 25 8 65 inches mm 5 Access the hood s wiring Route the 30 ft extension harness through the strain relief to the square mounting clip until i...

Page 19: ...r duct covers and assembly them Slide the edge of the duct cover under the clip located in the opposite duct cover Push them until you hear a click The bulges on the edge of the duct covers has to ent...

Page 20: ...in recirculation mode To Reduce the Risk of Fire and Shock use only conversion kit Model RECHMIB If it is not possible to vent cooking fumes and vapors to the outside the hood can be used in the non...

Page 21: ...isposable charcoal ilters that help remove smoke and odors Remove the grease ilter of the hood Position the charcoal ilter inside the structure of the motor as shown in picture Reinstall the grease il...

Page 22: ...e eShop www thermadoreshop com Order part number 00576697 DO NOT allow deposits to remain for long periods of time DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the...

Reviews: