ELECTRICAL
INSTALLATION
Warning: Switch power off at
service panel and lock the
service disconnecting means
before wiring this unit.
Wiring Remote Ventilator
VTR1000Q or VTR1400Q:
1.
Run five wires #14 AWG
(black, white, blue, red,
and green) in 1/2” conduit
from the remote ventilator
to the hood.
2.
Install conduit connector
at the end of the conduit.
Remove the knockout on
top of the junction box.
Attach conduit connector
to the junction box.
3.
Use the four wire bundle
and ground wire in the
junction box for
connecting to the remote
ventilator wires. Connect
black wire from the
remote ventilator to the
black wire in the junction
box, red to red, blue to
blue, white to white, and
green to green.
Do not
connect to the power
supply wire bundle
containing a black and
white wire. See Figure E.
Wiring To Power Supply:
1. Installation requires a
15A circuit.
Run three
wires: black, white, and
green using #14 AWG from
the service panel to the
junction box.
2.
Remove junction box cover
HNW
as shown in Figure E.
3.
Remove the knockout and
install
1
/
2
” conduit
connector.
4.
Connect black wire from
service panel to black in
junction box, white to
white, and green to
green. See Figure E.
5.
Close junction box cover.
Fig. E